77 Ill. Adm. Code 855.420
Remote Decontamination Enclosure System
Section 855
Section 855.420Â Remote
Decontamination Enclosure System
a)Â Â Â Â Â Â Â Â A remote worker or equipment decontamination enclosure system
may be used when the asbestos abatement work occurring in a contained area in a
school is restricted to the removal of nonfriable ACBM by a method which does
not cause the ACBM to become friable, or removal of thermal system insulation
by use of a glovebag technique.
b)Â Â Â Â Â Â Â Â Worker access to and from a contained area must be through an
airlock.
c)Â Â Â Â Â Â Â Â If a worker decontamination enclosure system attached to a
contained area is to be used as a remote decontamination enclosure system for
work conducted in other contained areas, access to the worker decontamination
enclosure system consisting of one of the following methods may be provided,
and shall be provided when it is not feasible for the equipment decontamination
enclosure system to be used for this purpose:
1)Â Â Â Â Â Â Â Â An airlock attached to the equipment room of the
decontamination enclosure system.
2)Â Â Â Â Â Â Â Â A two-stage airlock, consisting of two airlocks in series,
which provides access directly to the contained area connected to the worker
decontamination enclosure system.
3)Â Â Â Â Â Â Â Â If only nonfriable removal or removal by a glovebag technique
is to be conducted in the contaminated area having the attached worker
decontamination enclosure system, an airlock attached to the contained area.
d)Â Â Â Â Â Â Â Â Setup of the remote decontamination enclosure system shall be
in accordance with Section 855.410.
e)Â Â Â Â Â Â Â Â The remote decontamination enclosure system shall be located
inside the separation barriers and shall be in accordance with Section
855.430(b).
f)Â Â Â Â Â Â Â Â The following procedures shall be used with a remote
decontamination enclosure system:
1)Â Â Â Â Â Â Â Â Licensed asbestos workers shall don respiratory protection and
two pairs of protective coveralls prior to entering the contained removal area.
2)Â Â Â Â Â Â Â Â After completion of the removal and cleaning, the worker shall
HEPA vacuum the outer suit, enter the airlock, remove the outer suit and
dispose of it as asbestos-contaminated waste.
3)Â Â Â Â Â Â Â Â Still wearing the inner suit and respiratory protection, the
worker shall either proceed to another containment, don a second suit and
enter, or proceed to the remote decontamination enclosure system.
4)Â Â Â Â Â Â Â Â The remote decontamination enclosure system shall consist of a
five chamber unit as illustrated in Section 855.Appendix A, Illustration D.
5)Â Â Â Â Â Â Â Â A HEPA filtered negative air pressure unit shall be attached
to the remote decontamination enclosure system at the equipment room end. The
negative air unit shall be exhausted to the exterior of the building and shall
operate in accordance with Section 855.380.
6)Â Â Â Â Â Â Â Â The remote decontamination enclosure system shall be wet
cleaned after the completion of abatement and have a 12 hour settling period
prior to the collection of air samples.
7)Â Â Â Â Â Â Â Â One aggressive air sample shall be taken in the equipment room
and analyzed by phase contrast microscopy (PCM) for clearance following USEPA
Asbestos Hazard Emergency Response Act (AHERA) clearance standards. If the
decontamination enclosure system does not meet clearance requirements, then the
above mentioned procedure shall be repeated until clearance is obtained.