77 Ill. Adm. Code 870.150
Heating and Air Conditioning
Section 870.150Â Â Heating and Air Conditioning
All on-site installations of heating and air conditioning
systems shall meet the equipment manufacturer's specifications, comply with
local code, and be performed by qualified personnel approved or licensed by the
local jurisdiction for this work, a licensed manufactured home installer or the
homeowner.
a)Â Â Â Â Â Â Â Â Heating
Equipment. The heating systems for most homes are provided with the duct
systems installed. On-site installation consists of connecting the crossover
duct for multi-section homes. Crossover ducts for multi-section homes must be
supported aboveground, sealed to prevent air leaks and cut to length to avoid
kinks.
b)Â Â Â Â Â Â Â Â Air
Conditioning Equipment. Air conditioning equipment must be installed in
accordance with the manufacturer's specifications and comply with local codes.Â
The maximum electrical full load ampere draw for the desired air conditioning
unit must not exceed the home manufacturer's circuit rating. Any
field-installed wiring beyond the junction box must include a fused disconnect
located within sight of the condensing unit. The maximum fuse size is marked
on the condenser data plate. Charging of the air conditioning equipment must
be performed by qualified personnel. Condensation from the air conditioning
equipment must not drain underneath the home.
c)Â Â Â Â Â Â Â Â Clothes
dryer vents must exhaust outside the exterior of the home, or any perimeter
foundation or skirting. The exhaust duct must be adequately supported and
sealed. The installation of the duct must be in accordance with the
manufacturer's instructions.