77 Ill. Adm. Code 890.1480
Types of Fixture Trap Vents
Section 890
Section 890.1480Â Types of
Fixture Trap Vents
a)Â Â Â Â Â Â Â Â Individual Dry Vent is a single fixture trap vent only and
shall not be installed as part of a wet vent.
b)        Common Vent. A vertical common vent may be used for two
fixture traps if both traps connect with a vertical waste at the same level.Â
(See Appendix K.Illustration O.) Â A horizontal common vent may be used for two
fixture traps if both traps connect to the horizontal waste at the same point
and the vent is located downstream of the fixture connection. The horizontal
trap-to-vent distance shall comply with Appendix A.Table I. (See Appendix
K.Illustration O and Appendix A.Table I.)
c)Â Â Â Â Â Â Â Â Wet venting shall be installed in accordance with Section
890.1500.
d)Â Â Â Â Â Â Â Â Circuit
and loop venting shall be installed in accordance with Section 890.1520.
e)Â Â Â Â Â Â Â Â Combination
waste and vent systems shall be installed in accordance with Section 890.1590.
f)Â Â Â Â Â Â Â Â Island vent systems
shall be installed in accordance with Section 890.1600.