77 Ill. Adm. Code 890.330
Special Joints
Section 890
Section 890.330Â Special
Joints
a)        Copper Tubing to Screwed Pipe Joints. Joints from copper
tubing to threaded pipe shall be made by the use of a cast bronze or wrought
copper adaptor fitting. The joint between copper tubing and the fitting shall
be soldered or, if flared or compression, must be accessible.
b)        Welding or Brazing. Brazing or welding shall be in accordance
with the provisions of Section 6 of the Code for Pressure Piping, ASME B31.1.
c)        Slip Joints. In drainage and water piping, slip joints may be
used on the inlet side of the trap or in the trap seal, and on the exposed
fixture supply. Slip joints shall not be used in any inaccessible piping.Â
Push-on angle and straight stop valves are permitted, provided that they meet
the following specifications: they are installed by being pushed onto copper or
chlorinated polyvinyl chloride (CPVC); they are mechanically secured by metal
tabs that grip the piping; they are sealed with o-rings; and they are capable
of withstanding a water pressure of 150 psi and a temperature of 210 degrees
Fahrenheit.
d)        Expansion Joints. Expansion joints shall be accessible and
may be used where necessary to provide for expansion or contraction of the
piping. The expansion joint material shall conform to the type of piping on
which it is installed.
e)Â Â Â Â Â Â Â Â Compression type couplings shall not be used in unexposed
water piping except for water services, water meter yokes, and stop box
connections.
f)        Grooved Type Mechanical Couplings. Grooved type mechanical
couplings, in accordance with Section 890.320(p), may be used in potable water
and roof drain piping. These couplings shall not be used in waste, soil or
vent piping.
g)        Plastic Pipe to Non-Plastic Pipe Joints. Joints between
plastic pipe and non-plastic pipe shall be made only by one of the following
methods:
1)Â Â Â Â Â Â Â Â Pressure Piping
A)Â Â Â Â Â Â Â Approved insert fittings (in accordance with Appendix A.Table
A);
B)Â Â Â Â Â Â Â Threaded adaptors;
C)Â Â Â Â Â Â Â Flanges; or
D)Â Â Â Â Â Â Â Flared fittings.
2)        Non-pressure Piping − DWV
A)Â Â Â Â Â Â Â Caulked lead joints with caulked adaptors;
B)Â Â Â Â Â Â Â No-hub soil pipe shielded couplings with approved adaptor
having a raised bead;
C)Â Â Â Â Â Â Â Compression type joints for hub and spigot cast iron pipe; or
D)Â Â Â Â Â Â Â Threaded adaptors.