77 Ill. Adm. Code 890.340
Use of Joints
Section 890
Section 890.340Â Use of
Joints
a)        Clay Sewer Pipe. Joints in vitrified clay pipe or between vitrified
clay pipe and metal pipe shall be made with a neoprene gasket and stainless
steel bands or as provided in Section 890.320(f), (g) or (o), if applicable.
b)        Concrete Sewer Pipe. Joints in concrete sewer pipe or between
concrete sewer pipe and metal pipe shall be made with a neoprene gasket and
stainless steel bands or as provided in Section 890.320(f), (g) or (o), if
applicable.
c)        Cast Iron Pipe. A joint in cast iron water supply pipe shall
be made in accordance with Section 890.320(a) and (b) or shall be a mechanical
joint in accordance with AWWA C151. Joints in cast iron soil pipe shall be
made in accordance with Section 890.320(a), (b), (n), (o) or (p).
d)        Screw Pipe to Cast Iron. Joints between wrought iron, steel,
brass, or copper pipe and cast iron pipe shall be either caulked or threaded
joints that are made as provided in Section 890.320(a) or (b) and shall be made
with proper adaptor fittings.
e)        Lead to Cast Iron, Wrought Iron or Steel. Joints between lead
and cast iron, wrought iron, or steel pipe shall be made by means of wiped
joints to a caulking ferrule, soldering nipple, or bushing as provided in
Section 890.320(c).
f)        Copper Water Tube. Joints in copper tubing shall be made with
cast bronze or wrought copper pressure fittings, properly soldered or brazed,
or by means of compression or flared joints as provided in Sections 890.320(d),
(e), (h) and (p)(2). Flared joints and compression fittings shall not be
installed underground except for water services, water meter yokes, and stop box
connections.
g)        Plastic Pipe. Joints between plastic pipe and non-plastic
material shall be made only with an appropriate type adaptor as provided in
Section 890.320(l) and 890.330(g).
1)        Plastic-Commingling. There shall be no commingling of plastic
materials within the same plumbing system except through the use of proper
adaptors or approved solvent as listed in Appendix A.Table A, for connections
transitioning from one material to another, only.
2)        Plastic Pipe. Plastic pipe shall not be installed in any
tunnel or chase that contains uninsulated hot water, hot air or steam piping that
causes the ambient air temperature in the tunnel or chase to exceed 180 degrees
Fahrenheit.
h)        Building Sewer Connections. An elastomeric coupling seal
conforming to ASTM C 425, ASTM C 443, ASTM C 564, ASTM D 4161, ASTM F 477, ASTM
D 3139, ASTM D 3212, or ASTM D 412 tests may be used to adapt any two building
sewer pipes for different materials or size changes. The flexible couplings
shall be attached to the pipe with stainless steel clamps or bolts. The
manufacturer's recommended method of installation shall be followed.