77 Ill. Adm. Code 890.360
Water Closet and Pedestal Urinal
Section 890
Section 890.360Â Water Closet
and Pedestal Urinal
Fixture connections between
drainage pipes and water closets, floor outlet service sinks and pedestal
urinals, and earthenware trap standards shall be made by means of brass,
copper, hard lead, plastic, or iron flanges; caulked, soldered, screwed or solvent
welded to the drainage pipe. Flanges of hard lead, plastic and iron flanges
for no-hub or compression joints shall be secured to the floor. The connection
shall be bolted, with a gasket, washer or setting compound, between the
earthenware and the flange. The floor flange shall be set on an approved firm
base. The use of putty or non-drying plumber's putty manufactured specifically
for plumbing installation is acceptable.