77 Ill. Adm. Code 905.120
Disinfection
Section 905
Section 905.120Â Disinfection
a)Â Â Â Â Â Â Â Â As of January 1, 2014, the effluent from any new, repaired or
replaced private sewage disposal system that is designed and approved to have a
discharge point shall be disinfected prior to discharge.
b)        Chlorine Feeders. Chlorination equipment shall have a means
of removal of solids. Appendix A, Illustration S provides an example of a
typical chlorine feeder. All chlorine feeders shall meet the requirements of
Appendix A, Illustration S. Other feeders that meet the requirement of this
Section are also acceptable.
c)        Chlorine Contact Tanks. Chlorine contact tanks shall be
baffled and shall provide a contact time of at least 30 minutes based on 2½
times the average flow. The minimum contact tank capacity shall be 30
gallons. Access to the distribution feeder shall extend to the ground surface.
d)        Chlorine Residual. A final effluent free chlorine residual of
0.2 to 1.5 mg/1 shall be maintained.
e)Â Â Â Â Â Â Â Â Chlorine products used for the disinfection of treated
wastewater effluent shall be used according to the product's labeling.
f)Â Â Â Â Â Â Â Â After
January 1, 2014, any disinfection process or equipment that does not meet the
requirements of NSF International/ANSI Standard 46, Section 11 or does not
provide proper disinfection as determined by adequate third party testing will
not be approved for installation.
g)Â Â Â Â Â Â Â Â When
the private sewage disposal system incorporates a discharge to a subsurface
seepage system as a method to reduce the amount of effluent at the discharge
point, the disinfection device shall be the last component prior to the
discharge point.