77 Ill. Adm. Code 905.130
Human Waste Disposal
Section 905
Section 905.130Â Human Waste
Disposal
a)        General. Privies, portable toilets, recirculation toilets,
incinerator toilets and compost toilets are approved for private sewage
disposal of human wastes. Other domestic wastes shall be disposed of in a conventional
system (see Section 905.30); however, the size of all components, as designed
in accordance with Appendix A, Illustration A, may be reduced 25 percent
(except that septic tanks may not be smaller than 750 gallons). Note: Compost
toilets may be used to dispose of other organic domestic wastes.
b)        Privy Construction. All privies shall be constructed and
maintained in accordance with the following and Appendix A, Illustration T:
1)        Pit Construction. The pit shall be constructed of materials
and in a manner so as to be able to endure the anticipated load and use and to
withstand the local environmental conditions without deteriorating. The pit
shall be constructed so that there shall be access to the pit for pumping and
cleaning.
2)        Pit Size. The pit shall have a minimum capacity of 50 cubic
feet per seat.
3)        Floor and Seat Riser. The floor and seat riser shall be
constructed of an impervious material and in a manner to exclude insects and
rodents. The seat riser shall be bonded to the floor to prevent seepage through
the riser onto the floor.
4)        Seat Cover. The seat opening shall be covered with a hinged
lid that forms a tight seal.
5)        Vent. Each pit or vault privy shall be provided with a vent
to the outside that creates airflow out of the building through the vent. The
vent opening shall be screened with 16 mesh screen to prevent the entry of
flies and shall terminate through the roof.
6)        Maintenance. When any privy is filled to within 18 inches of
the bottom of the riser, it shall be pumped by a private sewage disposal system
pumping contractor.
7)Â Â Â Â Â Â Â Â Abandonment.Â
Privies that are no longer in use shall be completely pumped. The floor and
walls shall be cracked or crumbled so that the tank or pit will not hold water,
and the tank or pit shall be filled with sand or soil. If the tank or walls are
removed from the ground, the excavation shall be filled with soil.
c)        Vault Privy. Watertight, non-metal vaults are required where
privies are used in areas where the groundwater or limestone formations are
within 4 feet of the bottom of the pit. The vault shall be provided with a
readily accessible cleanout that prohibits the entry of rodents, insects and
surface water. (See Appendix A, Illustration T.)
d)        Septic Privy. The vault of a septic privy shall be
watertight. The subsurface seepage field shall consist of a minimum of one 10-foot
distribution line placed in a 2-foot wide trench constructed in accordance with
Section 905.60 and Appendix A, Illustration U.
e)Â Â Â Â Â Â Â Â Re-circulating Toilets
1)Â Â Â Â Â Â Â Â Self-contained toilets that treat and re-circulate the
flushing liquid shall be constructed of an impervious, easily cleanable
material and vented to the outside air through a screened pipe. The effluent,
if any, from the re-circulating toilet shall discharge into a subsurface
seepage field or into a disposal bag. The subsurface seepage field shall
consist of a minimum of one 10-foot long distribution line placed in a 2-foot
wide trench constructed in accordance with Section 905.60. The owner of a re-circulating
toilet shall dispose of any residual from the unit in an approved public or
private sewage disposal system.
2)Â Â Â Â Â Â Â Â Re-circulating toilets shall comply with the requirements of
the NSF International/ANSI Standard 41 and shall bear the NSF International or
the approved certification agency seal.
f)Â Â Â Â Â Â Â Â Incinerator Toilets
1)Â Â Â Â Â Â Â Â Incinerator toilets shall be designed and operated to provide
complete incineration of the contents without production of odors. The owner of
an incinerator toilet shall maintain the toilet and dispose of the contents in
accordance with Section 905.170(e).
2)Â Â Â Â Â Â Â Â Incinerator toilets shall comply with the requirements of NSF
International/ANSI Standard 41 and shall bear the NSF International or the
approved certification agency seal.
g)Â Â Â Â Â Â Â Â Compost Toilets
1)Â Â Â Â Â Â Â Â Compost toilets shall be designed in accordance with the
manufacturer's recommendations to serve the anticipated number of persons. The
owner of a compost toilet shall maintain the toilet and dispose of the contents
in accordance with Section 905.170.
2)Â Â Â Â Â Â Â Â Compost toilets shall comply with the requirements of NSF
International/ANSI Standard 41 and shall bear the NSF International or the
approved certification agency seal.