83 Ill. Adm. Code 730.525
Transmission Requirements
Section 730.525 Transmission
Requirements
Local exchange carriers shall
furnish and maintain plant, equipment and facilities to meet the following
minimum transmission standards. The transmission standards set forth in this
Section are based upon measurements from the network interface at the customer
premises through the local loop to a nominal 48-volt central office and
measured at a frequency of 1004 hertz.
a) Local line analog loops shall have a loop resistance not
exceeding the operating design of the associated central office equipment. Longer
loops may be used by deployment of loop range extenders.
b) All analog loops are to be maintained to a minimum of 40,000
ohms insulation resistance.
c) Transmission loss of analog local loop shall be engineered not
to exceed 10.0 dB when measured in accordance with subsection (a). The local
loop transmission loss shall be adjusted to 10.0 dB or less if it exceeds 10.0
dB.
d) Transmission loss in analog interoffice trunks shall be
engineered not to exceed 7 dB. If the loss exceeds expected design loss by +
or - 3.5 dB, it shall be corrected to within 1 dB of the design loss.
e) Transmission loss on analog toll terminating trunks shall be
engineered not to exceed 4 dB. If the loss exceeds expected design loss by +
or - 3.5 dB, it shall be corrected to within 1 dB of the design loss.
f) Transmission loss on all digital interoffice trunks shall be
engineered and maintained not to exceed 6 dB.
g) Loop current shall be maintained at 20 milliamperes or
greater.
h) Power influence (Noise to Ground) shall not exceed 90 dBrnc.
i) Circuit noise (Noise Metallic) shall not exceed 30 dBrnc.