8 Ill. Adm. Code 215.245
Transfer of Liquids
Section 215
Section 215.245 Transfer of
Liquids
a) A competent attendant shall supervise the transfer of liquids
from the time the connections are first made until they are disconnected.
b) Pumps shall be of a material suitable for use with the
solution being handled and designed to withstand the working pressure.
c) Air compressors may be used for transfer of nitrogen
fertilizer solutions.
1) The air compressor shall be protected with a back flow check
valve in the air line to prevent the flow of nitrogen fertilizer solutions or
vapor from the container into the air compressor.
2) A relief valve large enough to discharge the full capacity of
the compressor shall be connected to the discharge before any shutoff valve.
d) All storage installations shall be equipped with devices so as
to minimize tampering while installation is unattended.
e) Containers shall be filled or used only upon authorization of
owner or owner's agent.