8 Ill. Adm. Code 255.70
Agrichemical Facility Plans, Specifications and Records
Section 255
Section 255.70 Agrichemical
Facility Plans, Specifications and Records
a) The following records shall be maintained at the agrichemical
facility, and the records shall be available for review on request by the
Department:
1) A plot plan of the property showing all structures and the
location of all wells on the site.
2) A plot plan or map showing surface water runoff routes from
the agrichemical facility, approximate distance to and identity of nearby
lakes, streams, drainage ditches or storm drains, distance and direction to
nearest public and private wells, and site soil characteristics and groundwater
depth.
3) Tank schedule showing material of construction, capacity,
diameter, height, and product stored.
4) Secondary and operational area containment construction plans
and capacity of such structures in gallons. Manufacturer's confirmation of
compatibility with agrichemicals, and installation instructions if synthetic
liners or synthetic materials are used. Manufacturer's confirmation of
compatibility with agrichemical and estimate of life expectancy if
prefabricated basins are used.
5) Operational plan for containment areas showing the handling
and utilization of recovered agrichemical, rinse water, and precipitation
accumulation.
6) Storage and handling instructions on each pesticide handled in
bulk (i.e., registrant's instructions).
7) Spill reports on all reportable spills associated with the
agrichemical facility operation.
8) State inspection reports.
9) Agrichemical facility inspection and maintenance reports
required of the operation in Section 255.130.
b) Agrichemical facility specifications, records, plans or
reports required under any other State or Federal regulatory program and that
contain the information requested by subsection (a) may be used to fulfill this
recordkeeping requirement.
c) Non-commercial agrichemical facilities and on-farm storage
facilities are not covered by the recordkeeping provisions of this Section but
shall remain subject to inspection by the Department as is deemed necessary to
ensure compliance with the provisions of this Part.