8 Ill. Adm. Code 255.90
Operational Area Containment
Section 255
Section 255.90 Operational
Area Containment
a) Except as provided in Section 255.140, all transfer of
agrichemicals between containers, including loading, unloading, repackaging and
mixing, and equipment cleaning performed at an agrichemical facility or a
non-commercial agrichemical facility, shall be done with a containment system
designed to intercept, retain, and recover operational and accidental spillage,
leakage, wash water, and agrichemical residues. Materials of containment
structures shall be compatible with the products handled and maintained in a
condition to retain recovered material until it is used or properly disposed
of.
b) General requirements for permanent operational containment
structures consisting of floors, curbs, and walls include:
1) Floors, curbs, and walls of a permanent operational
containment structure shall be constructed of reinforced concrete or other
materials compatible with the agrichemical being handled.
2) A permanent operational area containment structure shall be
sealed or otherwise maintained to provide a rate of permeability not to exceed
1 x 10
-6
centimeters per second.
3) Cracks and seams that develop shall be repaired and sealed.
4) Storm water drainage shall be diverted away from all permanent
containment structures.
c) Loading area containment: Total loading area containment
volume shall be equal to or greater than the volume of the largest tank to be
loaded in the loading area. If the loading area containment area is not
protected from contact with precipitation, the containment volume shall be equal
to or greater than the volume generated by a 6 inch rain storm (a 25 year, 24
hour storm). The loading area containment volume requirements may be achieved
with a curbed containment area and catch basin or in combination with above
ground tanks connected to an automatic sump pump transfer system or by gravity
flow where elevation or installation allows.
d) Unloading area containment: Total unloading area containment
volume shall be a minimum of 25 gallons. The loading area containment may be
used as the unloading area containment. Individual catchment basins or
portable containers may be used to meet the requirements of this Section. The
individual basins or portable containers shall be placed to catch and recover
spillage and leakage from transfer connections and pumps.
e) Mixing and repackaging area container: Mixing and repackaging
containment areas shall provide curbing or other means (e.g., basins) to
intercept, retain, and recover agrichemicals spilled or leaked during mixing
and repackaging operations.
f) Cleaning and washing area containment: Cleaning and washing
of agrichemical residue from handling, processing and application equipment at
an agrichemical facility or a non-commercial agrichemical facility shall be
done utilizing an operational containment system or structure. Cleaning and
washing containment may be accomplished at the loading containment area. If a
separate cleaning and washing area is used, it shall be designed to intercept,
retain and recover all wash water and agrichemical residue containing
pesticides.
g) Transfer structures and systems: The use of underground
structures or pits for storage of rinsates, washwater or recycle liquid is
prohibited. This prohibition includes scale pits but does not include sumps or
wet wells containing pumps used for transfer of spilled agrichemicals, rinse
waters or wash waters to containment, holding or recycle systems. Sumps or wet
wells are structures that have detention times of 72 hours or less. Sumps or
wet wells shall be constructed and maintained to provide a rate of permeability
not to exceed 1 x 10
-6
centimeters per second. Sumps and wet wells
shall be inspected for cracks and leaks and sealed immediately if any cracks or
leaks are found.