8 Ill. Adm. Code 257.70
General Class Permits for Central Distribution Facilities
Section 257
Section 257.70 General Class
Permits for Central Distribution Facilities
a) There shall be an agrichemical facility general class permit
available for issuance by the Department to an owner or operator of a central
distribution facility. In addition to completed application forms available
from the Department, a submittal for an agrichemical facility general class
permit shall include a location area map, a detailed plot plan of the facility,
engineering plans of the containment structures, and any additional information
the applicant or the Department deems necessary to fully describe the project.
b) All filled mini-bulks and packaged goods at a central
distribution facility shall be warehoused in a designated secondary containment
structure on a surface with a hydraulic conductivity not to exceed 1 X 10
-6
cm/sec constructed and 10
-5
cm/sec maintained. The surface shall be
constructed of an impervious material compatible with the products being stored
and capable of being properly decontaminated. There shall not be penetrations
in the floor and all existing floor drains shall be sealed with a non-shrink
grout.
c) The designated secondary containment structure shall include a
minimum of a four (4)-inch curb or other flow-diverting structure or system to
allow for the interception and retention of spilled materials within the secondary
containment area. The minimum four (4)-inch curb or other flow-diverting
structure or system shall completely surround the designated secondary
containment structure.