92 Ill. Adm. Code 436.40
Inspection Procedures for COVID-19 Related Equipment
Section 436.40 Inspection Procedures for COVID-19
Related Equipment
Personal protective equipment and COVID-19 related signage
may be installed on any vehicle covered by this Part. If installed, the
equipment and signage shall be inspected according to this Section.
a) Hand Sanitizer Dispenser
PROCEDURES/SPECIFICATIONS:
Dispenser must be securely
installed in the driver/entry area, either behind the handrail or just to the
right of the driver on the vertical portion of the dash in a location where
hand sanitizer cannot drip or leak onto the entryway or passenger walkway. The
dispenser must not be mounted as to cause a catch point to passengers as they
enter or exit the bus.
Dispenser must be
labeled with the words "sanitizer" or "hand sanitizer".
REJECT VEHICLE IF:
Dispenser is not securely
installed in the driver/entry area, either behind the handrail or just to the
right of the driver on the vertical portion of the dash.
Dispenser is installed in a
location where it drips or leaks onto the entryway or passenger walkway.
Dispenser is mounted in a way to
cause a catch point to passengers as they enter or exit the bus.
Required label is
missing.
b) Driver Protective
Barrier
PROCEDURES/SPECIFICATIONS:
A driver
protective barrier panel may be installed directly behind the driver. The
panel must be mounted to the wall of the bus as flush as practicable.
If
installed, the passenger seat directly behind the driver must be rendered
inoperative (this can be accomplished by removing the lower seat cushion) to
comply with FMVSS 571.222. If the lower seat cushion is removed, all exposed
seat frame must be padded in compliance with FMVSS 571.302. The panel shall be
constructed of clear material compliant with FMVSS 571.302, such as
polycarbonate. The end of the barrier panel exposed to the passenger
compartment shall be secured to a padded stanchion extending from floor to the
ceiling. The stanchion shall be attached to the roof bow or a reinforced panel
in the ceiling and a solid connection point on the floor. The barrier panel
shall be in compliance with FMVSS 571.302 and FMVSS 571.222.
REJECT VEHICLE IF:
The barrier is installed in a
location other than directly behind the driver or not flush to the wall of the
bus. The passenger seat directly behind the driver is operative with a barrier
installed or the lower seat cushion has been removed with padding installed
that is not in compliance with FMVSS 571.302. Barrier is not constructed,
secured, or padded in compliance with FMVSS 571.222 and 571.302.
c) COVID-19 Related
Lettering/Signage
PROCEDURES/SPECIFICATIONS:
Lettering/signage that relates to
COVID-19 (e.g., assigned seating for students, social distancing, face
coverings, guidelines adopted by the bus operator, etc.) may be installed on
the interior of the bus. The lettering may be installed on the forward face of
seat backs or seat cushions, ceiling, or bulkhead and shall not interfere with
other required lettering.
REJECT VEHICLE IF:
Lettering or signage is installed
on the exterior of the bus or in a place other than the forward face of seat
backs or seat cushions, ceiling, or bulkhead.
Lettering or
signage obstructs other required lettering.