92 Ill. Adm. Code 436.APPENDIX A
A Air Cleaner through Barrier, Guard
Section 436.APPENDIX A Air Cleaner through Barrier,
Guard
a) AIR CLEANER
PROCEDURES/SPECIFICATIONS:
Any type is
acceptable.
REJECT VEHICLE IF:
Air cleaner is not
properly attached or is missing.
b) AISLE
PROCEDURES/SPECIFICATIONS:
Unobstructed minimum clearance
leading from service door to emergency door (or back of bus) must be at least
12 inches (305 mm) wide. Floor to ceiling height must be a minimum of 68.9
inches (1.75 m) at any location within the aisle.
REJECT VEHICLE IF:
Aisle does not
meet minimum standards.
c) ALTERNATOR (GENERATOR)
PROCEDURES/SPECIFICATIONS:
The generator, or alternator with
rectifier, shall have a minimum capacity rating of 60 amperes and shall be
capable of meeting all electrical requirements.
REJECT VEHICLE IF:
Alternator does
not meet minimum standards or is not functioning.
d) AXLES
PROCEDURES/SPECIFICATIONS:
Must meet federal chassis
requirements as indicated on federal certification label. (See 49 CFR 568.)
REJECT VEHICLE IF:
Axles show visible signs of
apparent damage, leaking fluids or are not firmly attached.
e) BARRIER, GUARD
PROCEDURES/SPECIFICATIONS:
A guard barrier, constructed and
thickly padded so as to provide head, knee and leg protection, shall be
installed in front of each forward facing passenger seat that does not directly
face the rear surface of another passenger seat. The barrier must measure the
same height as the passenger seat back directly behind that barrier. (See 49
CFR 571.222.)
REJECT VEHICLE IF:
Barrier is not solidly attached.
Padding or covering is missing or shows wear and tear. Barrier does not meet
requirements.