355 IAC 3-10-4
355 IAC 3-10-4 Tool bar refrigeration units
Cite as Ind. Admin. Code tit. 355, r. 3-10-4
Sec. 4. (a) The manufacturer of a tool bar refrigeration unit shall provide traceable documentation of recommended operation and
maintenance procedures for any refrigeration unit manufactured after the effective date of this rule.
(b) Tool bar refrigeration units shall be:
(1) constructed of corrosion resistant materials; and
(2) installed, maintained, and operated in accordance with the manufacturer's specifications and limitations for
use.
(c) A manual shutoff valve, meeting the requirements of 355 IAC 3-2-5(a), shall be installed directly upon the inlet of the heat
exchanger so that the operator may close the shutoff valve to prevent any backflow of refrigerated ammonia through the delivery line from the heat
exchanger unit while connecting, disconnecting, or otherwise servicing the tool bar breakaway device. The manual shutoff valve may be a quick-acting shutoff valve.