355 IAC 3-10-5
355 IAC 3-10-5 Pressure gauges
Cite as Ind. Admin. Code tit. 355, r. 3-10-5
Sec. 5. (a) A pressure gauge, graduated from zero (0) to sixty (60) psig, shall be installed in communication with any manifold for
application knives that receive nonrefrigerated ammonia. The pressure gauge may be remotely located from the manifold for the convenience of
the applicator.
(b) A pressure gauge, graduated from zero (0) to four hundred (400) psig, shall be installed at a conspicuous location near the breakaway
device between the tool bar breakaway device and the next shutoff device on the meter side of the breakaway.