355 IAC 3-10-5

355 IAC 3-10-5 Pressure gauges

Last amended: 2025Year: 2027Length: 87 wordsOfficial source

Cite as Ind. Admin. Code tit. 355, r. 3-10-5

Sec. 5. (a) A pressure gauge, graduated from zero (0) to sixty (60) psig, shall be installed in communication with any manifold for application knives that receive nonrefrigerated ammonia. The pressure gauge may be remotely located from the manifold for the convenience of the applicator. (b) A pressure gauge, graduated from zero (0) to four hundred (400) psig, shall be installed at a conspicuous location near the breakaway device between the tool bar breakaway device and the next shutoff device on the meter side of the breakaway.
355 IAC 3-10-5: 355 IAC 3-10-5 Pressure gauges | Justis AI