675 IAC 15-2-24

675 IAC 15-2-24 Room and hallway sizes

Last amended: 2023Year: 2027Length: 122 wordsOfficial source

Cite as Ind. Admin. Code tit. 675, r. 15-2-24

Sec. 24. (a) Every mobile structure used for living or sleeping purposes shall have at least one habitable room with not less than one hundred fifty (150) square feet of gross floor area. Rooms designed for sleeping purposes shall have a minimum gross square foot floor area as follows: One Person 50 Two persons 70 Each person in excess of two 50 (b) No habitable room, except a kitchen, shall be less than five feet (5') in any clear horizontal dimension. (c) Each toilet compartment shall be a minimum of thirty inches (30") in width and have at least twenty-one inches (21") of clear space in front of each toilet. (d) Hallways shall have a minimum horizontal dimension of twenty-eight inches (28").