- 675 IAC 15-2-1675 IAC 15-2-1 Title, classification, availability, and applicability of rule
- 675 IAC 15-2-2675 IAC 15-2-2 Definitions
- 675 IAC 15-2-3675 IAC 15-2-3 Source of design and construction standards
- 675 IAC 15-2-4675 IAC 15-2-4 Scope of design and construction standards
- 675 IAC 15-2-5675 IAC 15-2-5 Basic principles of design and construction
- 675 IAC 15-2-6675 IAC 15-2-6 Definitions for design and construction
- 675 IAC 15-2-7675 IAC 15-2-7 General design and construction requirements
- 675 IAC 15-2-8675 IAC 15-2-8 Design dead loads
- 675 IAC 15-2-9675 IAC 15-2-9 Design live loads
- 675 IAC 15-2-10675 IAC 15-2-10 Wind, roof, and snow loads
- 675 IAC 15-2-11675 IAC 15-2-11 Fastening of structural systems
- 675 IAC 15-2-12675 IAC 15-2-12 Walls
- 675 IAC 15-2-13675 IAC 15-2-13 Floors
- 675 IAC 15-2-14675 IAC 15-2-14 Design load deflection
- 675 IAC 15-2-15675 IAC 15-2-15 Structural load tests
- 675 IAC 15-2-16675 IAC 15-2-16 Weather resistance
- 675 IAC 15-2-17675 IAC 15-2-17 Condensation resistance for residential systems
- 675 IAC 15-2-18675 IAC 15-2-18 Interior walls, partitions, and ceilings
- 675 IAC 15-2-19675 IAC 15-2-19 Rodent resistance
- 675 IAC 15-2-20675 IAC 15-2-20 Heat loss; mobile system
- 675 IAC 15-2-21675 IAC 15-2-21 Design considerations
- 675 IAC 15-2-22675 IAC 15-2-22 Ceiling height
- 675 IAC 15-2-23675 IAC 15-2-23 Exits
- 675 IAC 15-2-24675 IAC 15-2-24 Room and hallway sizes
- 675 IAC 15-2-25675 IAC 15-2-25 Glass and glazed openings
- 675 IAC 15-2-26675 IAC 15-2-26 Smoke detectors
- 675 IAC 15-2-27675 IAC 15-2-27 Smoke detector locations
- 675 IAC 15-2-28675 IAC 15-2-28 Alarm sounding devices
- 675 IAC 15-2-29675 IAC 15-2-29 Detector trouble signals
- 675 IAC 15-2-30675 IAC 15-2-30 Testing detectors
- 675 IAC 15-2-31675 IAC 15-2-31 In-transit design requirements
- 675 IAC 15-2-32675 IAC 15-2-32 Scope of plumbing standards
- 675 IAC 15-2-33675 IAC 15-2-33 Basic principles of plumbing standards
- 675 IAC 15-2-34675 IAC 15-2-34 Definitions for plumbing standards
- 675 IAC 15-2-35675 IAC 15-2-35 General plumbing requirements
- 675 IAC 15-2-36675 IAC 15-2-36 Protection of plumbing system
- 675 IAC 15-2-37675 IAC 15-2-37 Material standards
- 675 IAC 15-2-38675 IAC 15-2-38 Joints and connections
- 675 IAC 15-2-39675 IAC 15-2-39 Traps
- 675 IAC 15-2-40675 IAC 15-2-40 Cleanouts
- 675 IAC 15-2-41675 IAC 15-2-41 Fixtures and connections
- 675 IAC 15-2-42675 IAC 15-2-42 Toilets; shower compartments; dishwashers; washing machines
- 675 IAC 15-2-43675 IAC 15-2-43 Installation of fixtures
- 675 IAC 15-2-44675 IAC 15-2-44 Piping strains and stresses
- 675 IAC 15-2-45675 IAC 15-2-45 Piping supports
- 675 IAC 15-2-46675 IAC 15-2-46 Hangers and anchors
- 675 IAC 15-2-47675 IAC 15-2-47 Water supply piping; hot water supply system
- 675 IAC 15-2-48675 IAC 15-2-48 Water connections and outlets
- 675 IAC 15-2-49675 IAC 15-2-49 Water heaters; relief valves; prohibited location
- 675 IAC 15-2-50675 IAC 15-2-50 Material standards for water piping and fittings
- 675 IAC 15-2-51675 IAC 15-2-51 Installation of piping
- 675 IAC 15-2-52675 IAC 15-2-52 Size of water supply piping
- 675 IAC 15-2-53675 IAC 15-2-53 Drainage systems; materials
- 675 IAC 15-2-54675 IAC 15-2-54 Drain outlets
- 675 IAC 15-2-55675 IAC 15-2-55 Drain connections
- 675 IAC 15-2-56675 IAC 15-2-56 Size of drainage piping
- 675 IAC 15-2-57675 IAC 15-2-57 Wet-vented drainage system
- 675 IAC 15-2-58675 IAC 15-2-58 Offsets and branch fittings
- 675 IAC 15-2-59675 IAC 15-2-59 Grade of horizontal drainage piping
- 675 IAC 15-2-60675 IAC 15-2-60 Vent piping and fittings
- 675 IAC 15-2-61675 IAC 15-2-61 Material standards for vent piping and fittings
- 675 IAC 15-2-62675 IAC 15-2-62 Size of vent piping
- 675 IAC 15-2-63675 IAC 15-2-63 Anti-siphon trap vent
- 675 IAC 15-2-64675 IAC 15-2-64 Horizontal vent connections and grade
- 675 IAC 15-2-65675 IAC 15-2-65 Vent terminal
- 675 IAC 15-2-66675 IAC 15-2-66 Vent caps
- 675 IAC 15-2-67675 IAC 15-2-67 Water pressure tests
- 675 IAC 15-2-68675 IAC 15-2-68 Waste and vent system tests
- 675 IAC 15-2-69675 IAC 15-2-69 Fixture tests
- 675 IAC 15-2-70675 IAC 15-2-70 Shower compartment tests
- 675 IAC 15-2-71675 IAC 15-2-71 Scope of heating, cooling, and fuel-burning system standards
- 675 IAC 15-2-72675 IAC 15-2-72 Definitions for heating, cooling, and fuel-burning systems
- 675 IAC 15-2-73675 IAC 15-2-73 LP-gas systems; service line pressure
- 675 IAC 15-2-74675 IAC 15-2-74 LP-gas containers
- 675 IAC 15-2-75675 IAC 15-2-75 Oil tanks
- 675 IAC 15-2-76675 IAC 15-2-76 Gas piping systems
- 675 IAC 15-2-77675 IAC 15-2-77 Oil piping systems
- 675 IAC 15-2-78675 IAC 15-2-78 General appliance standards
- 675 IAC 15-2-79675 IAC 15-2-79 Gas clothes dryers
- 675 IAC 15-2-80675 IAC 15-2-80 Installation of appliances
- 675 IAC 15-2-81675 IAC 15-2-81 Venting and combustion air systems
- 675 IAC 15-2-82675 IAC 15-2-82 Operating instructions
- 675 IAC 15-2-83675 IAC 15-2-83 Appliance information
- 675 IAC 15-2-84675 IAC 15-2-84 Access to appliances
- 675 IAC 15-2-85675 IAC 15-2-85 Location of appliances
- 675 IAC 15-2-86675 IAC 15-2-86 Clearances
- 675 IAC 15-2-87675 IAC 15-2-87 Circulating air system
- 675 IAC 15-2-88675 IAC 15-2-88 Scope of electrical standards
- 675 IAC 15-2-89675 IAC 15-2-89 Definitions for electrical standards
- 675 IAC 15-2-90675 IAC 15-2-90 Power supply
- 675 IAC 15-2-91675 IAC 15-2-91 Disconnecting means and branch-circuit protective equipment
- 675 IAC 15-2-92675 IAC 15-2-92 Receptacle outlets
- 675 IAC 15-2-93675 IAC 15-2-93 Fixtures; appliances
- 675 IAC 15-2-94675 IAC 15-2-94 Wiring methods and materials
- 675 IAC 15-2-95675 IAC 15-2-95 Grounding
- 675 IAC 15-2-96675 IAC 15-2-96 Insulated neutral
- 675 IAC 15-2-97675 IAC 15-2-97 Equipment grounding
- 675 IAC 15-2-98675 IAC 15-2-98 Bonding of noncurrent-carrying metal parts
- 675 IAC 15-2-99675 IAC 15-2-99 Electrical tests
- 675 IAC 15-2-100675 IAC 15-2-100 Load calculations