675 IAC 15-2-54

675 IAC 15-2-54 Drain outlets

Last amended: 2023Year: 2027Length: 153 wordsOfficial source

Cite as Ind. Admin. Code tit. 675, r. 15-2-54

Sec. 54. (a) Clearance from Drain Outlet. The drain outlet shall be provided with a minimum clearance of three inches (3") in any direction from all parts of the structure or appurtenances and with not less than eighteen inches (18") unrestricted clearance directly in front of the drain outlet. (b) Drain Connector. The drain connector shall not be smaller than the piping to which it is connected and shall be equipped with a watertight cap or plug matching the drain outlet. The cap or plug shall be permanently attached to the mobile structure or drain outlet. (c) The drain outlet and drain connector shall not be less than three inches (3") inside diameter. (d) Preassembly of Drain Lines. Drain lines, provided by the manufacturer located under the mobile structure designed to bring the drain system to one distribution point and which may be damaged in transit, must be designed for proper site assembly.