675 IAC 15-2-56
675 IAC 15-2-56 Size of drainage piping
Cite as Ind. Admin. Code tit. 675, r. 15-2-56
Sec. 56. Fixture Load. Except as provided by 675 IAC 15-2-52, drain pipe sizes shall be determined by the type of fixture
and the total number connected to each drain.
(1) Fixture Unit. A one and one-half inch (1 1/2") minimum diameter piping shall be required for one (1) and not more than three (3)
individually vented fixtures.
(2) Fixture Unit. A two inch (2") minimum diameter piping shall be required for four (4) or more fixtures individually
vented.
(3) A three inch (3") minimum diameter piping shall be required for toilets.
(4) When a combination of two (2) or more water closets, sinks, showers, urinals, or clothes washing equipment are installed, the
Indiana plumbing code shall apply for mobile system-commercial transitory plumbing systems.