326 IAC 15-1-2

326 IAC 15-1-2 Source-specific provisions

Last amended: 2026Year: 2027Length: 939 wordsOfficial source

Cite as Ind. Admin. Code tit. 326, r. 15-1-2

Sec. 2. (a) The sources listed in this subsection shall comply with the following emission and operating provisions: Source Emission Unit Emission Limitation lbs/hr (1) Indiana Oxide Corporation, Brazil Barton #1 reactor 0.215 Barton #2 reactor 0.215 Barton #3 reactor 0.215 Barton #4 reactor 0.215 Rake furnace 0.006 (2) Hammond Lead Products, Inc., Stack 4A-S-8 0.053 HLP-Lead Plant Stack 14-S-16 0.053 Stack 1-S- 2 0.053 Stack 1-S- 26 0.053 Stack 16-S- 56 0.200 Stack 1-S- 52 0.070 Stack 1-S- 27 0.020 Stack 4-S- 35 0.090 Stack 6-S- 33 0.070 Stack 4B-S- 34 0.080 Stack 6-S- 47 0.021 Stack V- 1 0.090 (A) The ventilator control system (Stack V-1) shall consist of a fan with a constant flow rate that draws air from the building through a HEPA filter which vents to the atmosphere through a stack. The HEPA filters shall be maintained and operated in order to achieve maximum control efficiency. In addition to the requirements contained in subsection (c), Hammond Lead Products, Inc. shall submit an operation and maintenance plan by July 31, 1990, which incorporates good housekeeping practices for the ventilator control systems. This operation and maintenance plan shall be incorporated into the operating permits for Hammond Lead Products, Inc. and submitted to U.S. EPA as a revision to Indiana's lead state implementation plan by December 31, 1990. The ventilator control systems shall be designed so that process fugitive emissions will not routinely escape the buildings except as vented through the ventilator control systems. The compliance test method specified in section 4(a) of this rule shall be used to determine compliance with the emission limitations for the ventilator control system stacks. (B) By December 31, 1989, the stack heights for all processes except Stack 16-S-56, Stack 1-S-52, and the ventilator control systems shall be no less than sixty (60) feet above grade; the stack heights for Stack 16-S-56 and Stack 1-S-52 shall be no less than eighty-two (82) feet above grade. By July 31, 1990, the stack heights for the other ventilator control systems shall be no less than sixty (60) feet above grade. (C) Hammond Lead Products, Inc. shall install HEPA filters according to the following schedule: Stack 4A-S-8 March 31, 1992 Stack 14-S-16 June 30, 1992 Stack 1-S-2 December 31, 1991 Stack 1-S-26 September 30, 1992 *Stack 16-S-56: 130 bag filter November 20, 1989 100 bag filter December 6, 1989 80 bag filter June 1, 1989 72 bag filter December 31, 1991 Stack 1-S-52 December 31, 1989 Stack 1-S-27 August 15, 1987 Stack 4-S-35 October 16, 1989 Stack 6-S-33 July 22, 1988 Stack 4B-S-34 October 5, 1989 Stack 6-S-47 May 26, 1988 *Four (4) bag filters are vented through common Stack 16-S-56. (D) Hammond Lead Products, Inc. shall provide written notification to the commissioner within three (3) days after the installation of HEPA filters is completed at each of the sites listed in clause (A). (E) All emission limitations in this subdivision shall be met by December 31, 1992. (F) This subdivision shall be submitted to U.S. EPA as a revision to the Indiana state implementation plan. Source Emission Unit Emission Limitation lbs/hr (3) Hammond Group-Halstab Division Stack S-1 0.04 Stack S- 2 0.03 Stacks S-4, S-5 (each) 0.07 Stacks S-6, S-7, S-8 (each) 0.05 Stacks S-9, S-10, S-11 (each) 0.04 S-12, S-13 (each) 0.04 S-14, S-15, S-16 (each) 0.04 Stacks S-17, S-21 (each) 0.07 (A) Hammond Group-Halstab Division shall install and maintain one (1) baghouse with laminated filters followed by one (1) HEPA filter in series with the baghouse on each of stacks S-1, S-2, S-4 through S-17, and S-21. (B) Hammond Group-Halstab Division shall submit a proposed ambient monitoring and quality assurance plan within thirty (30) days of March 10, 1988. (C) Hammond Group-Halstab Division shall commence ambient monitoring within thirty (30) days of the department's approval of the proposed ambient monitoring and quality assurance plan. (D) Hammond Group-Halstab Division shall conduct a minimum of twenty-four (24) months of monitoring for lead. The monitoring shall be: (i) performed using U.S. EPA-approved methods, procedures, and quality assurance programs; and (ii) in accordance with the ambient monitoring and quality assurance plan as approved by the department. (E) The requirement to monitor shall expire twenty-four (24) months from the commencement date of the monitoring provided the monitored values, averaged over a calendar quarter, do not exceed eighty percent (80%) of the National Ambient Air Quality Standards (NAAQS) level for lead in any quarter during twenty-four (24) months. (F) If the monitored values averaged over a calendar quarter exceed eighty percent (80%) of the NAAQS level for lead during the twenty- four (24) month period, monitoring shall be continued until eight (8) continuous quarters of monitored values do not exceed eighty percent (80%) of the NAAQS level for lead. (G) If the monitored values, averaged over a calendar quarter, exceed eighty percent (80%) of the NAAQS level for lead for two (2) or more continuous quarters, the department and Hammond Group-Halstab Division shall analyze and assess causes of the emissions and determine whether changes to control requirements or operating practices are appropriate. (b) In addition to the sources listed in subsection (a), C & D Batteries, Attica, shall comply with subsection (c) and section 3 of this rule. (c) Operation and maintenance programs shall be designed to prevent deterioration of control equipment performance. For sources listed in subsection (a)(1) through (a)(3), these programs shall be submitted to the department on or before June 1, 1987. For the source listed in subsection (b), these programs shall be submitted to the department on or before February 1, 1988. These programs will be incorporated into the individual source operation permits.
326 IAC 15-1-2: 326 IAC 15-1-2 Source-specific provisions | Justis AI