LAC 43:XI.4705
LAC 43:XI.4705. Testing of Components (Formerly §1705)
Cite as La. Admin. Code tit. 43, pt. XI, § 4705
A. Each hydrostatic test under §4703 must test all pipe and attached fittings, including components, unless otherwise permitted by Subsection B of this Section.
B. A component that is the only item being replaced or added to the pipeline system need not be hydrostatically tested under Subsection A of this Section if the manufacturer certifies that either:
1. the component was hydrostatically tested at the factory; or
2. the component was manufactured under a quality control system that ensures each component is at least equal in strength to a prototype that was hydrostatically tested at the factory.