LAC 51:XXIV.303

LAC 51:XXIV.303. Dimensional Design [formerly paragraph 24:005]

Last amended: 2002Year: 2026Length: 118 wordsOfficial source

Cite as La. Admin. Code tit. 51, pt. XXIV, § 303

A. There shall be construction tolerances allowed on all dimensional designs. Overall length, width, and depth in the deep end may vary plus or minus 3 inches. All other overall dimensions may vary plus or minus two inches), unless otherwise specified (such as in a Class A pool). The designed waterline shall have a maximum construction tolerance at the time of completion of the work of plus or minus 1/4 inch for pools with adjustable weir surface skimming systems, and of plus or minus 1/8 inch for pools with non-adjustable surface skimming systems. B. The size of Class A or Class D pools shall be governed by the requirements of the activities for which the installation is intended.
LAC 51:XXIV.303: LAC 51:XXIV.303. Dimensional Design [formerly paragraph 24:005] | Justis AI