LAC 51:XXIV.305

LAC 51:XXIV.305. Walls [formerly paragraph 24:005-1]

Last amended: 2002Year: 2026Length: 79 wordsOfficial source

Cite as La. Admin. Code tit. 51, pt. XXIV, § 305

A. Walls in Class B and Class C pools shall not be greater than 11° from plumb for a minimum depth of 2 feet 9 inches from the waterline in deep areas, or for a minimum depth of 2 feet 3 inches in the shallow areas. Below these depths, the wall may be radiused to join the floor. Class A pools, where racing lanes terminate, shall have plumb walls. (A maximum 1° from plumb construction tolerance shall be allowed.)
LAC 51:XXIV.305: LAC 51:XXIV.305. Walls [formerly paragraph 24:005-1] | Justis AI