310 CMR 15.241
System Venting
Systems to be located either in whole or in part under driveways, parking or turning areas or
other areas of impervious material shall be designed to achieve proper venting of the system
according to the following criteria:
(a) the disposal area distribution system shall be piped to the atmosphere using the same
diameter pipe as the distribution system;
(b) the vent pipe shall be designed to prevent entrance of animals or precipitation and shall
be backfilled tightly to prevent seepage of surface water into the system;
(c) the vent pipe shall be located beyond the limit of the impervious area subject to
vehicular traffic;
(d) where trenches, fields or beds are used, the end of each distribution lateral shall be
connected to one or more vent(s);
(e) where pits are used, the vent shall extend under the cover of the pit; and
(f) the riser and above ground components of the vent shall be constructed of durable,
non-corrosive materials.