105 CMR 120.318
Inspection and Maintenance of Radiation Machines, Radiographic Exposure Devices, Transport
and Storage Containers, Associated Equipment, Source Changers, and Survey Instruments
(A) The radiographer shall perform visual and operability checks on survey meters, radiation
machines, radiographic exposure devices, transport and storage containers, associated equipment
and source changers before each day’s use, or work shift, to ensure that:
(1) The equipment is in good working condition;
(2) The sources are adequately shielded; and,
(3) Required labeling is present.
(B) Survey instrument operability must be performed using check sources or other appropriate
means.
(C) If equipment problems are found, the equipment must be removed from service until
repaired.
(D) Each licensee or registrant shall have written procedures for and perform inspection and
routine maintenance of radiation machines, radiographic exposure devices, source changers,
associated equipment, transport and storage containers, and survey instruments at intervals not
to exceed three months or before the first use thereafter to ensure the proper functioning of
components important to safety. If equipment problems are found, the equipment must be
removed from service until repaired.
(E) The licensee’s inspection and maintenance program must include procedures to assure that
Type B packages are shipped and maintained in accordance with the certificate of compliance
or other approval.
(F) Records of equipment problems and of any maintenance performed under 105 CMR
120.318 must be made in accordance with 105 CMR 120.366