105 CMR 120.643
Access Control
(A) Each entrance to a radiation room at a panoramic irradiator must have a door or other
physical barrier to prevent inadvertent entry of personnel if the sources are not in the shielded
position. Product conveyor systems may serve as barriers as long as they reliably and
consistently function as a barrier. It must not be possible to move the sources out of their
shielded position if the door or barrier is open. Opening the door or barrier while the sources are
exposed must cause the sources to return promptly to the shielded position. The personnel
entrance door or barrier must have a lock that is operated by the same key used to move the
sources. The doors and barriers must not prevent any individual in the radiation room from
leaving.
(B) In addition, each entrance to a radiation room at a panoramic irradiator must have an
independent backup access control to detect personnel entry while the sources are exposed.
Detection of entry while the sources are exposed must cause the sources to return to their fully
shielded position and must also activate a visible and audible alarm to make the individual
entering the room aware of the hazard. The alarm must also alert at least one other individual
who is onsite of the entry. That individual shall be trained on how to respond to the alarm and
prepared to promptly render or summon assistance.
(C) A radiation monitor must be provided to detect the presence of high radiation levels in the
radiation room of a panoramic irradiator before personnel entry. The monitor must be integrated
with personnel access door locks to prevent room access when radiation levels are high.
Attempted personnel entry while the monitor measures high radiation levels, must activate the
alarm described in 105 CMR 120.643(B). The monitor may be located in the entrance (normally
referred to as the maze) but not in the direct radiation beam.
(D) Before the sources move from their shielded position in a panoramic irradiator, the source
control must automatically activate conspicuous visible and audible alarms to alert people in the
radiation room that the sources will be moved from their shielded position. The alarms must
give individuals enough time to leave the room before the sources leave the shielded position.
(E) Each radiation room at a panoramic irradiator must have a clearly visible and readily
accessible control that would allow an individual in the room to make the sources return to their
fully shielded position.
(F) Each radiation room of a panoramic irradiator must contain a control that prevents the
sources from moving from the shielded position unless the control has been activated and the
door or barrier to the radiation room has been closed within a preset time after activation of the
control.
(G) Each entrance to the radiation room of a panoramic irradiator and each entrance to the area
within the personnel access barrier of an underwater irradiator must be posted as required by 105
CMR 120.238. Radiation postings for panoramic irradiators must comply with the posting
requirements of 105 CMR 120.238, except that signs may be removed, covered, or otherwise
made inoperative when the sources are fully shielded.
(H) If the radiation room of a panoramic irradiator has roof plugs or other movable shielding,
it must not be possible to operate the irradiator unless the shielding is in its proper location. The
requirement may be met by interlocks that prevent operation if shielding is not placed properly
or by an operating procedure requiring inspection of shielding before operating.
(I) Underwater irradiators must have a personnel access barrier around the pool which must
be locked to prevent access when the irradiator is not attended. Only operators and facility
management may have access to keys to the personnel access barrier. There must be an intrusion
alarm to detect unauthorized entry when the personnel access barrier is locked. Activation of the
intrusion alarm must alert an individual (not necessarily onsite) who is prepared to respond or
summon assistance.