105 CMR 120.659
Design Requirements
Irradiators whose construction began after July 1, 1993, must meet the design requirements of
105 CMR 120.659.
(A) Shielding: For panoramic irradiators, the licensee shall design shielding walls to meet
generally accepted building code requirements for reinforced concrete and design the walls, wall
penetrations, and entranceways to meet the radiation shielding requirements of 105 CMR
120.645. If the irradiator will use more than five million curies (2 x 10 becquerels) of activity,
the licensee shall evaluate the effects of heating of the shielding walls by the irradiator sources.
(B) Foundations: For panoramic irradiators, the licensee shall design the foundation, with
consideration given to soil characteristics, to ensure it is adequate to support the weight of the
facility shield walls.
(C) Pool Integrity: For pool irradiators, the licensee shall design the pool to assure that it is leak
resistant, that it is strong enough to bear the weight of the pool water and shipping casks, that a
dropped cask would not fall on sealed sources, that all outlets or pipes meet the requirements of
105 CMR 120.653(B), and that metal components are metallurgically compatible with other
components in the pool.
(D) Water Handling System: For pool irradiators, the licensee shall verify that the design of
the water purification system is adequate to meet the requirements of 105 CMR 120.653(E). The
system must be designed so that water leaking from the system does not drain to unrestricted
areas without being monitored.
(E) Radiation Monitors: For all irradiators, the licensee shall evaluate the location and
sensitivity of the monitor to detect sources carried by the product conveyor system as required
by 105 CMR 120.649(A). The licensee shall verify that the product conveyor is designed to stop
before a source on the product conveyor would cause a radiation overexposure to any person.
For pool irradiators, if the licensee uses radiation monitors to detect contamination under
105 CMR 120.679(B), the licensee shall verify that the design of radiation monitoring systems
to detect pool contamination includes sensitive detectors located close to where contamination
is likely to concentrate.
(F) Source Rack: For pool irradiators, the licensee shall verify that there are no crevices on the
source or between the source and source holder that would promote corrosion on a critical area
of the source. For panoramic irradiators, the licensee shall determine that source rack drops due
to loss of power will not damage the source rack and that source rack drops due to failure of
cables (or alternate means of support) will not cause loss of integrity of sealed sources. For
panoramic irradiators, the licensee shall review the design of the mechanism that moves the
sources to assure that the likelihood of a stuck source is low and that, if the rack sticks, a means
exists to free it with minimal risk to personnel.
(G) Access Control: For panoramic irradiators, the licensee shall verify from the design and
logic diagram that the access control system will meet the requirements of 105 CMR 120.643.
(H) Fire Protection: For panoramic irradiators, the licensee shall verify that the number,
locations, and spacing of the smoke and heat detectors are appropriate to detect fires and that the
detectors are protected from mechanical and radiation damage. The licensee shall verify that the
design of the fire extinguishing system provides the necessary discharge patterns, densities, and
flow characteristics for complete coverage of the radiation room and that the system is protected
from mechanical and radiation damage.
(I) Source Return: For panoramic irradiators, the licensee shall verify that the source rack will
automatically return to the fully shielded position if offsite power is lost for more than ten
seconds.
(J) Seismic: For panoramic irradiators to be built in seismic areas, the licensee shall design the
reinforced concrete radiation shields to retain their integrity in the event of an earthquake by
designing to the seismic requirements of an appropriate source such as American Concrete
Institute Standard ACI 318-89, Building Code Requirements for Reinforced Concrete, Chapter
21, Special Provisions for Seismic Design, or local building codes, if current.
(K) Wiring: For panoramic irradiators, the licensee shall verify that electrical wiring and
electrical equipment in the radiation room are selected to minimize failures due to prolonged
exposure to radiation.