R 408.10664
R 408.10664 Ramps.
Cite as Mich. Admin. Code R 408.10664
Rule 664. (1) A ramp may be a component in a means of egress when it conforms to
the requirements of this part. A ramp which is constructed after June 15, 1990, and which
is less than the minimum measurements prescribed in this rule shall not be considered as
an approved part of a means of egress.
(2) A ramp and the platforms and landings associated therewith shall be designed for
not less than 100 pounds per square foot live load.
(3) The slope of a ramp shall not vary between landings. A landing shall be level
and the changes in direction of travel, if any, shall be made only at landings.
(4) A ramp in a building that is more than 3 stories in height shall be made of
noncombustible construction. A ramp floor and landings shall be solid and without
perforations.
(5) A ramp shall have a nonslip surface.
(6) A ramp shall have a minimum width of 44 inches and a maximum slope of 1
inch in 12 inches.