R 408.14522
R 408.14522 Machine controls.
Cite as Mich. Admin. Code R 408.14522
Rule 4522. (1) An operating control on a machine, except a stop button, shall be so
located or guarded to prevent accidental contact.
(2) A machine requiring more than 1 operator shall have controls for each operator
which shall be activated concurrently before the machine will operate as prescribed in
R 408.14541(1).
(3) A machine shall be provided at each work station with a non-concealed
emergency stop device distinguished by its size or color.
(4) A machine shall be equipped so that upon power failure it will not automatically
restart upon restoration of the power.
(5) An automatic die casting machine shall be equipped with a time delay device or
circuit that will prevent the machine from recycling if more than 2 seconds delay occurs
between the automatic demand for recycle and its commencement. It shall be necessary
for the operator to reset the controls before the machine will restart. Other equivalent
means may be used that will prevent recycling until the machine is cleared if the intent of
this subrule is met.
(6) A safety interlock, exposed to contact, shall be guarded against accidental
actuation.