R 408.14523
R 408.14523 Hydraulic and pneumatic systems.
Cite as Mich. Admin. Code R 408.14523
Rule 4523. (1) Flexible and rigid hydraulic and pneumatic piping and its component
parts shall have a designed safety factor of not less than 4 and shall be maintained to
prevent leaks that constitute a hazard.
(2) A hydraulic pressure relief valve shall be provided on each separate system and
set to open at a pressure of not more than 10% above the maximum operating
pressure. The discharge of the valve shall not create a hazard for the employee. A die
casting machine shall not be operated with the pressure relief valve removed.
(3) Fire resistant fluid shall be used in equipment where failure of a hydraulic
system could cause ignition of the fluid by molten metal or flame.
(4) Hydraulic and pneumatic lines shall be protected from damage due to chafing or
pinching.