R 408.16247
R 408.16247 Plastic scrap granulators.
Cite as Mich. Admin. Code R 408.16247
Rule 6247. (1) The opening of a hopper of a plastic scrap granulator shall be of
such distance from the cutting knives that the fingers of an employee cannot make
contact. A baffle gate shall be installed at the feed entrance of a hopper so that the
opening is normally closed except for charging with scrap.
(2) An access opening for maintenance, cleaning or inspection shall be covered
with a solid plate, secured by a fastener which requires the use of a tool to unfasten it.
(3) Before a hopper is removed, a plastic scrap granulator shall have the power
source disconnected and locked out.