R 408.41221
R 408.41221 Stilts.
Cite as Mich. Admin. Code R 408.41221
Rule 1221. (1) A stilt shall be inspected for damage, wear, and corrosion. A
defective stilt, including the pins and straps, shall be repaired or replaced before being
placed in use.
(2) Stilts shall be used only if all of the following conditions exist:
(a) Floors are level.
(b) All floor holes are securely covered.
(c) When an employee is using stilts, the top edge height of the top rail, or
equivalent member, shall be increased an amount equal to the height of the stilts.
(d) The floor is capable of supporting a load on the stilt’s base plate without
deformation of more than 1/4 of an inch.
(e) The floor is cleared of debris, materials, or liquids that could cause a slipping or
tripping hazard.
(3) Stilts shall not be used while going from one level to another.
(4) An employee may wear stilts on a scaffold only if it is a large area scaffold.