R 408.42033
R 408.42033 Means of egress.
Cite as Mich. Admin. Code R 408.42033
Rule 2033. (1) When an employee is required to be inside a structure being
demolished, only a means of egress designated by the employer shall be used and
maintained. All other means of egress shall be closed off.
(2) The means of egress shall be free of hazards. During manual demolition,
the means of egress shall be supplied with an illumination intensity of not less than
10 candlepower.
(3) A means of egress shall be guarded to protect an employee from falling
material.
(4) An employee entrance to a multistory structure to be demolished shall be
protected by a roof canopy for a distance of not less than 8 feet from the structure. The
canopy shall be not less than 1 foot wider on each side than the entrance and shall be
capable of sustaining a load of 150 pounds per square foot.