R 408.42034
R 408.42034 Material chutes and drops.
Cite as Mich. Admin. Code R 408.42034
Rule 2034. (1) The area onto and through which material is to be dropped shall be
completely enclosed with barricades not less than 42 inches high and not less than 6 feet
back from the opening and the area receiving the material. Signs warning of the hazard of
falling materials shall be posted on the barricades at each level containing the barricades.
(2) Where material is dropped through more than 1 level, the opening shall be enclosed
between the upper and lower levels, an enclosed chute shall be provided, or the
intermediate levels shall be barricaded as prescribed in subrule (1) of this rule. If the drop
is more than 40 feet inside the building, only an enclosed opening or chute shall be used.
The chute or enclosure shall extend through the ceiling of the receiving level.
(3) A material chute shall be constructed to withstand any impact load imposed on it
without failure.
(4) A material chute, or section thereof, at an angle of more than 45 degrees from the
horizontal shall be entirely enclosed, except for an opening equipped with a closure at or
about each floor level for insertion of materials. The opening shall not be more than 48
inches in height measured along the wall of the chute. At all stories below the top floor,
the openings shall be kept closed when not in use. The chute shall fit the floor or wall
opening or the open space shall be closed.
(5) Where material is dumped from mechanical equipment or a wheelbarrow, a toeboard
or bumper not less than 4 inches thick by 6 inches high nominal size secured to the floor
shall be provided at each material chute opening.