R 299.2445
R 299.2445 Groundwater monitoring system.
Cite as Mich. Admin. Code R 299.2445
Rule 2445. (1) The supervisor of mineral wells may require a surface facility installed or
substantially modified after the effective date of these rules to have 1 of the following
monitoring systems to detect leakage from secondary containment areas:
(a) A minimum of 1 groundwater monitoring well downgradient, which is in close
proximity to all secondary containment areas and completed at depths as specified in the
hydrogeological investigation, so as to intercept any discharge from the secondary
containment area to groundwater contained in a usable aquifer.
(b) Tertiary containment underlying the secondary containment which shall be
constructed and sealed in a manner to capture any waste product, stored product or brine
that may leak or seep through the secondary containment. A layer of permeable material
and a monitoring tube shall be placed between the secondary and tertiary containment to
allow monitoring to determine the presence of any leakage or seepage through the
secondary containment.
(2) A monitoring well installed under subrule (1)(a) of this rule shall be subject to the
following provisions:
(a) The drilling method shall be specified.
(b) Monitoring wells completed in fine-textured earth materials shall have special
construction, such as gravel packing around the screen, or other construction methods
approved by the supervisor of mineral wells.
(c) Monitoring wells shall have suitable equipment and methods for sampling
groundwater, as specified in the hydrogeological investigation.
(d) Casings shall be installed so as to prevent vertical leakage of fluids between the casing
and the drill hole and shall be capped and provided with a cap locking device. Use of a
vented cap is desirable, but care shall be taken to prevent introduction of contaminants
through such vents.
(e) The well casing shall be protected against accidental damage and shall be adequately
marked so as to be clearly visible during winter and summer conditions.
(f) When a monitoring well is to be permanently abandoned, approved plugging
procedures shall be followed as provided in part 127 of 1978 PA 368, MCL 333.12701 et
seq.
(3) The monitoring system required by subrule (1) of this rule shall be kept in a functional
condition. Water samples shall be collected and water level measurements taken once every
twelfth month. The water samples shall be tested for the parameters specified in R
299.2443(1)(a). Results of analyses and water level measurements shall be submitted to
the supervisor of mineral wells within 60 days of taking the sample or making the water
level measurement.