R 299.2446
R 299.2446 Secondary containment; general requirements.
Cite as Mich. Admin. Code R 299.2446
Rule 2446. Secondary containment measures at a wellhead or surface facility shall meet
all of the following requirements:
(a) The sidewalls and floor of a secondary containment area shall be constructed and
sealed in a manner to prevent the seepage of waste product, stored product, or brine into
the surrounding soils, surface waters, or groundwater.
(b) Dikes or firewalls shall be maintained and the enclosure kept free of waste products,
stored products, tank bottoms, brine, water, vegetation, debris, and any flammable or
combustible material.
(c) The containment volume shall be the larger of 11% of the total capacity of all vessels
or 111% of the capacity of the largest vessel located in a secondary containment area. For
the purposes of this subdivision, the largest vessel is either the largest single vessel or those
vessels connected in such a way to allow unrestricted gravity flow from vessel to vessel.
(d) A permittee shall install an automatic surface facility shutdown system if the facility
has a through put of liquids in a 24-hour period that exceeds the containment volume of
the secondary containment area. The automatic shutdown system shall be designed to
prevent liquids from overflowing the secondary containment area. A surface facility shall
be exempt from the requirement of an automatic shutdown system if the facility has staff
present while operating and is equipped with alarm systems on the storage tank or tanks.
(e) All transfer and injection pumps shall have leak containment constructed to prevent
the seepage of any liquids moved by the pump or any lubricating oils into the surrounding
soils, surface waters, or groundwater.
(f) Wellheads and flare stacks shall have secondary containment and spill containment
areas constructed in a manner to prevent the seepage of waste product, stored product, or
brine into the surrounding soils, surface waters, or groundwater. Secondary containment at
the wellhead shall be constructed in a manner to capture leakage of liquid that may occur.
In addition, if the wellhead is equipped with a pump jack utilizing a gasoline or diesel-
powered engine, then the engine shall also have secondary containment that is sufficient to
prevent the seepage of any machine oils or fuels into the surrounding soils, surface waters,
or groundwater.
(g) A permittee shall keep secondary containment areas free of standing liquid. All spills
in a secondary containment area shall be pumped up within 48 hours of discovering the
spill.
(h) A permittee shall submit for the supervisor of mineral wells' approval, a plan for
inspections and monitoring of active wells and surface facilities.