R 325.2141
R 325.2141 Inlets.
Cite as Mich. Admin. Code R 325.2141
Rule 41. (1) A swimming pool owner shall ensure that a swimming pool water inlet
system has inlets adequate in design, number, and location to ensure uniform distribution
of treated water throughout the swimming pool.
(2) A swimming pool owner shall ensure that an inlet meets all of the following
requirements:
(a) Is equipped for flow rate adjustment.
(b) Does not extend from the swimming pool wall or floor so as to create a hazard.
(c) Is not less than 12 inches below the water level or is not less than 6 inches below the
water level and designed to direct the flow downward.
(3) A swimming pool owner shall ensure that a pool has the following number of inlets:
(a) Not less than 2 inlets.
(b) Not less than 1 inlet per 20 lineal feet of swimming pool periphery, except at a river
ride pool.
(c) More inlets than required in subdivision (a) or (b) of this subrule if necessary for the
uniform circulation of water.
(4) A swimming pool owner shall ensure that the location of inlets for a swimming pool
other than a river ride pool or a water slide pool is as follows:
(a) For a wall inlet system, inlets shall be spaced not more than 20 feet apart as measured
along the swimming pool wall.
(b) For a floor inlet system, inlets shall be uniformly spaced not more than 20 feet apart
and there shall be an inlet not more than 15 feet from each wall.
(c) Where water circulation might be impaired, there shall be at least 1 inlet located in
each recessed stairwell, underwater seat, or other space.
(5) A river ride pool or water slide pool owner shall provide a pool with 1 or more inlets
adequate in number and location to provide and maintain flow rates and water quality in
accordance with R 325.2194.