R 325.2142
R 325.2142 Main and other outlets.
Cite as Mich. Admin. Code R 325.2142
Rule 42. (1) A swimming pool owner shall ensure that a swimming pool has 2 or more
main outlets for the recirculation system pump for continuous removal of water for
treatment and for emptying the pool.
(2) A swimming pool owner shall ensure that the main outlets for the recirculation system
pump meet all of the following requirements:
(a) Are designed and located to ensure the complete draining of the pool.
(b) Are designed and located to prevent entrapment and to prevent the restriction of flow
by the simultaneous covering of all outlets on the system by 1 person.
(c) Do not extend from the swimming pool floor or wall so as to create a hazard.
(d) Are covered with a grate which is not hazardous to bathers, which is secured in place,
and which is removable only with tools.
(e) Have an open area for each grate large enough to assure water entrance velocities of
not more than 2 feet per second, with as close as practical to equal flow through each outlet
grate.
(f) Have the total open area for all main outlet grates large enough to assure water entrance
velocities of not more than 1 foot per second.
(g) Are interconnected with unrestricted piping that does not contain valves.
(3) If another pump or pumps are provided, then a swimming pool owner shall ensure that
the same outlet system supplying water to the pumps complies with the requirements of
subrules (2)(b), (c), (d), (e), (f), and (g) of this rule.
(4) A swimming pool owner shall ensure that all outlet openings meet both of the
following requirements:
(a) Are not less than 3 feet nor more than 20 feet from another outlet as measured center
to center.
(b) Are provided not more than 15 feet from a sidewall for a main outlet.
(5) A swimming pool owner shall ensure that all outlet discharge piping is valved in the
equipment room as close as practical to the pump suction.