R 336.1604
R 336.1604 Storage of organic compounds having true vapor pressure of more than 1.5 psia, but less than 11 psia, in existing fixed roof stationary vessels of more than 40,000-gallon capacity.
Cite as Mich. Admin. Code R 336.1604
Rule 604. (1) After April 30, 1981, it is unlawful for a person to store any organic compound
having a true vapor pressure of more than 1.5 psia, but less than 11 psia, at actual storage conditions
in any existing fixed roof stationary vessel of more than 40,000-gallon capacity, unless 1 of the
following conditions is met:
(a) The vessel is a pressure tank capable of maintaining working pressures sufficient to prevent
organic vapor or gas loss to the atmosphere at all times, except under emergency conditions.
(b) The vessel is equipped and maintained with a floating cover or roof which rests upon, and is
supported by, the liquid being contained and has a closure seal or seals to reduce the space between
the cover or roof edge and the vessel wall. The seal or any seal fabric shall not have visible holes,
tears, or other nonfunctional openings.
(c) The vessel is equipped and maintained with a vapor recovery system, or other control system
approved by the department, which recovers not less than 90%, by weight, of the uncontrolled
organic vapor that would otherwise be emitted into the atmosphere.
(2) All openings, except stub drains, in any stationary vessel subject to the provisions of this rule
shall be equipped with covers, lids, or seals so that all of the following conditions are met:
(a) The cover, lid, or seal is in the closed position at all times, except when in actual use.
(b) Automatic bleeder vents are closed at all times, except when the roof is floated off, or landed
on, the roof leg supports.
(c) Rim vents, if provided, are set at the manufacturer's recommended setting or are set to open
when the roof is being floated off the roof leg supports.