10 CSR 10-5.500
Control of Emissions From Volatile Organic Liquid Storage
PURPOSE: This rule limits the volatile
organic compound (VOC) emissions from
installations with volatile organic liquid storage vessels in the St. Louis 1997 eight (8)-
hour ozone nonattainment area by incorporating reasonably available control technology (RACT) as required by the Clean Air Act
Amendments (CAAA) of 1990.
PUBLISHER’S NOTE: The secretary of state
has determined that the publication of the
entire text of the material which is incorporated by reference as a portion of this rule would
be unduly cumbersome or expensive. This
material as incorporated by reference in this
rule shall be maintained by the agency at its
headquarters and shall be made available to
the public for inspection and copying at no
more than the actual cost of reproduction.
This note applies only to the reference material. The entire text of the rule is printed here.
(1) Applicability.
(A) This rule applies throughout the City
of St. Louis and St. Charles, St. Louis,
Jefferson, and Franklin Counties.
(B) This rule applies to all storage vessels
with a capacity greater than or equal to forty
thousand (40,000) gallons that are used to
store volatile organic liquid (VOL) with the
following exceptions:
1. Except as specified in subsections
(4)(E) and (4)(H) of this rule, storage vessels
with a capacity greater than or equal to forty
thousand (40,000) gallons storing a liquid
with a maximum true vapor pressure less
than one-half (0.5) psia are exempt from the
provisions of this rule; and
2. Except as specified in subsections
(4)(E) and (4)(H) of this rule, storage vessels
with a design capacity less than forty thousand (40,000) gallons are exempt from the
provisions of this rule.
(C) This rule does not apply to the following:
1. Vessels permanently attached to
mobile vehicles such as trucks, railcars,
barges, or ships;
2. Vessels used to store beverage alcohol;
3. Pressure vessels designed to operate
in excess of twenty-nine and four-tenths
(29.4) psia and without emissions to the
atmosphere;
4. Vessels at coke oven by-product
plants;
5. Vessels used only to store or transfer
petroleum liquids and that are subject to the
requirements of 10 CSR 10-5.220; and
6. Vessels used to store volatile organic
liquids that are subject to or exempt from the
requirements of 40 CFR 60, 61, or 63.
(2) Definitions.
(A) Beverage alcohol—Consumable products and their process intermediates and byproducts, consisting of ethanol or mixtures of
ethanol and non-volatile organic liquids.
(B) Closed vent system—A system that is
not open to the atmosphere and is composed
of piping, ductwork, connections, and, if
necessary, flow inducing devices that transport gas or vapor from an emission point to a
control device.
(C) Condensate—Hydrocarbon liquid separated from natural gas that condenses due to
changes in the temperature or pressure, or
both, and remains liquid at standard conditions.
(D) Control device—An enclosed combustion device, vapor recovery system, or flare.
(E) Control equipment—Any equipment
that reduces the quantity of a pollutant that is
emitted to the air. The device may destroy or
secure the pollutant for subsequent recovery.
Includes, but is not limited to, incinerators,
carbon adsorbers, and condensers.
(F) Department—The Missouri Department
of Natural Resources, which includes the
director thereof, or the person or division or
program within the department delegated the
authority to render the decision, order, determination, finding, or other action that is subject to review by the commission.
(G) Director—Director of the Missouri
Department of Natural Resources or a representative designated to carry out the duties as
described in 643.060, RSMo.
(H) External floating roof—A storage vessel cover in an open top tank consisting of a
double deck or pontoon single deck which
rests upon and is supported by petroleum liquid being contained and is equipped with a
closure seal(s) to close the space between the
roof edge and tank wall.
(I) Facility—All contiguous or adjoining
property that is under common ownership or
control, including properties that are separated
only by a road or other public right-of-way.
(J) Federally enforceable—All limitations
and conditions which are enforceable by the
administrator, including those requirements
developed pursuant to 40 CFR 55, 60, 61,
and 63; requirements within any applicable
state implementation plan; requirements in
operating permits issued pursuant to 40 CFR
70 or 71, unless specifically designated as
nonfederally enforceable; and any permit
requirements established pursuant to 40 CFR
52.10, 52.21, or 55, or under regulations
approved pursuant to 40 CFR 51, subpart I,
including operating permits issued under a
U.S. Environmental Protection Agencyapproved program that is incorporated into
the state implementation plan and expressly
requires adherence to any permit issued
under such program.
(K) Fill—The introduction of VOL into a
storage vessel but not necessarily to complete
capacity.
(L) Internal floating roof—A product cover
in a fixed roof tank which rests upon or is
floated upon the volatile organic compound
liquid being contained and which is equipped
with a sliding seal(s) to close the space
between the edge of the covers and tank shell.
(M) Liquid-mounted seal—A foam- or liquid-filled seal mounted in contact with the liquid between the wall of the storage vessel and
the floating roof continuously around the circumference of the tank.
(N) Maximum true vapor pressure—The
equilibrium partial pressure exerted by the
volatile organic compounds in the stored
volatile organic liquid (VOL) at the temperature equal to the highest calendar-month average of the VOL storage temperature for VOLs
stored above or below the ambient temperature or at the local maximum monthly average temperature as reported by the National
Weather Service for VOLs stored at the ambient temperature, as determined—
1.
In
accordance
with
methods
described in American Petroleum Institute
Bulletin 2517, Evaporation Loss From
External Floating Roof Tanks (incorporated
by reference in section (5));
2. As obtained from standard reference
texts;
3. As determined by ASTM D2879-83,
96, or 97 (incorporated by reference in section (5)); or
4. Any other method approved by the
director.
(O) Mechanical shoe seal—A metal sheet
held vertically against the wall of the storage
vessel by springs or weighted levers and is
connected by braces to the floating roof. A
flexible coated fabric (envelope) spans the
annular space between the metal sheet and
the floating roof.
(P) Petroleum—The crude oil removed
from the earth and the oils derived from tar
sands, shale, and coal.
(Q) Petroleum liquids—Petroleum, condensate, and any finished or intermediate
products manufactured in a petroleum refinery.
(R) Petroleum refinery—Any facility
engaged in producing gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants,
or other products through distillation of
petroleum or through redistillation, cracking,
extracting, or reforming of unfinished
petroleum derivatives.
(S) Reid vapor pressure—The absolute
vapor pressure of volatile crude oil and
volatile nonviscous petroleum liquids except
liquified petroleum gases, as determined by
ASTM D323-82 or 94 (incorporated by reference in section (5)).
(T) Rim seal—A device attached to the rim
of a floating roof deck that spans the annular
space between the deck and the wall of the
storage vessel. When a floating roof has only
one (1) such device, it is a primary seal;
when there are two (2) seals (one (1) mounted
above the other), the lower seal is the primary
seal and the upper seal is the secondary seal.
(U) Standard conditions—A gas temperature of seventy degrees Fahrenheit (70 °F) and
a gas pressure of fourteen and seven-tenths
(14.7) pounds per square inch absolute (psia).
(V) Storage vessel—Any tank, reservoir, or
container used for the storage of volatile
organic liquids, but does not include:
1. Frames, housing, auxiliary supports,
or other components that are not directly
involved in the containment of liquids or
vapors; or
2. Subsurface caverns or porous rock
reservoirs.
(W) Vapor-mounted seal—A rim seal
designed not to be in contact with the stored
liquid. Vapor-mounted seals may include, but
are not limited to, resilient seals and flexible
wiper seals.
(X) Vapor Recovery system—An individual
unit or series of material recovery units, such
as absorbers, condensers, and carbon adsorbers, used for recovering volatile organic
compounds.
(Y) Volatile organic compound (VOC)—
See definition in 10 CSR 10-6.020.
(Z) Volatile organic liquid (VOL)—Any
substance which is a liquid at storage conditions containing one (1) or more volatile
organic compounds.
(3) General Provisions.
(A) Every owner or operator storing VOL
in a vessel of forty thousand (40,000) gallons
or greater with a maximum true vapor pressure greater than or equal to one-half (0.5)
psia but less than three-quarters (0.75) psia
shall be subject to the record keeping requirements in subsection (4)(F) of this rule and the
monitoring requirements in subsection (4)(G)
of this rule. Furthermore, every owner or
operator storing VOL in a vessel of forty
thousand (40,000) gallons or greater with a
maximum true vapor pressure equal to threequarters (0.75) psia but less than eleven and
one-tenth (11.1) psia shall reduce VOC emissions from storage vessels as follows:
1. Equip each fixed roof storage vessel
with a vapor control system that meets the
specifications
contained
in
paragraph
(3)(A)3. of this rule or an internal floating
roof that meets the following specifications:
A. The internal floating roof shall rest
or float on the liquid surface but not necessarily in complete contact with it inside a
storage vessel that has a fixed roof. The internal floating roof shall be floating on the liquid surface at all times, except during initial
fill and during those intervals when the storage vessel is completely emptied and subsequently refilled. When the roof is resting on
the leg supports, the process of filling, emptying, or refilling shall be continuous and
accomplished as rapidly as possible;
B. Each internal floating roof shall be
equipped with one (1) of the following closure devices between the wall of the storage
vessel and the edge of the internal floating
roof:
(I) A liquid-mounted seal;
(II) Two (2) seals mounted one (1)
above the other so that each forms a continuous closure that completely covers the space
between the wall of the storage vessel and the
edge of the internal floating roof. The lower
seal may be vapor-mounted, but both must be
continuous; or
(III) A mechanical shoe seal;
C. Each opening in a non-contact
internal floating roof except for automatic
bleeder vents such as vacuum breaker vents
and the rim space vents shall provide a projection below the liquid surface;
D. Each opening in the internal floating roof except for leg sleeves, automatic
bleeder vents, rim space vents, column wells,
ladder wells, sample wells, and stub drains
shall be equipped with a cover or lid which is
to be maintained in a closed position at all
times with no visible gap except when the
device is in actual use. The cover or lid shall
be equipped with a gasket. Covers on each
access hatch and automatic gauge float well
shall be bolted except when they are in use;
E. Automatic bleeder vents shall be
equipped with a gasket and remain closed at
all times when the roof is floating except
when the roof is being floated off or is being
landed on the roof leg supports;
F. Rim space vents shall be equipped
with a gasket and set to open only when the
internal floating roof is not floating or at the
manufacturer’s recommended setting;
G. Each penetration of the internal
floating roof for the purpose of sampling a
sample well with a slit fabric cover that covers
Specific to the St. Louis Metropolitan Area
at least ninety percent (90%) of the opening;
and
H. Each penetration of the internal
floating roof that allows for passage of a ladder shall have a gasketed sliding cover;
2. Each external floating roof storage
vessel shall meet the following specifications:
A. Each external floating roof shall be
equipped with a closure device between the
wall of the storage vessel and the roof edge.
The closure device shall consist of two (2)
seals, one (1) above the other. The lower seal
is referred to as the primary seal, and the
upper seal is referred to as the secondary
seal.
(I) Except as provided in subparagraph (3)(C)2.D. of this rule, the primary
seal shall completely cover the annular space
between the edge of the floating roof and
storage vessel wall and shall be either a liquid-mounted seal or a mechanical shoe seal.
(II) The secondary seal shall completely cover the annular space between the
external floating roof and the wall of the storage vessel in a continuous fashion except as
allowed in subparagraph (3)(C)2.D. of this
rule;
B. Except for automatic bleeder vents
and rim space vents, each opening in a noncontact external floating roof shall provide a
projection below the liquid surface. Except
for automatic bleeder vents, rim space vents,
roof drains, and leg sleeves, each opening in
the roof shall be equipped with a gasketed
cover, seal, or lid that is to be maintained in
a closed position at all times with no visible
gap except when the device is in actual use.
Automatic bleeder vents shall be closed at all
times when the roof is floating except when
the roof is being floated off or is being landed
on the roof leg supports. Rim vents shall be
set open when the roof is being floated off the
roof leg supports or at the manufacturer’s
recommended setting. Automatic bleeder
vents and rim space vents shall be gasketed.
Each emergency roof drain shall include a
slotted membrane fabric cover that covers at
least ninety percent (90%) of the area of the
opening; and
C. The roof shall be floating off the
roof leg supports on the liquid at all times
except when the storage vessel is completely
emptied and subsequently refilled. The process of filling, emptying, or refilling when
the roof is resting on the leg supports shall be
continuous and accomplished as rapidly as
possible;
3. Closed vent systems and control
devices respectively shall meet the following
specifications:
A. The closed vent system shall be
designed to collect all VOC vapors and gases
discharged from the storage vessel and operated with no detectable emissions as indicated by an instrument reading of less than five
hundred parts per million (500 ppm) above
background and visual inspections, as determined by the methods in 40 CFR 60.485(c),
as specified in 10 CSR 10-6.070(3)(A)1.; and
B. The control device shall be
designed and operated to reduce inlet VOC
emissions by ninety percent (90%) or greater.
If a flare is used as the control device, it shall
meet the specifications described in the general control device requirements of 40 CFR
60.18, as specified in 10 CSR 106.070(3)(A)1.; or
4. An alternative emission control plan
equivalent to the requirements of paragraphs
(3)(A)1., (3)(A)2., or (3)(A)3. of this rule
that has been approved by the department and
the United States Environmental Protection
Agency in a federally enforceable permit.
(B) The owner or operator of each storage
vessel with a design capacity equal to or
greater than forty thousand (40,000) gallons
which contains VOL that, as stored, has a
maximum true vapor pressure greater than or
equal to eleven and one-tenth (11.1) psia
shall equip each storage vessel with a closed
vent system and control device as specified in
paragraph (3)(A)3. of this rule.
(C) Testing Requirements. The owner or
operator of each storage vessel specified in
section (1) of this rule shall comply with the
requirements of paragraph (3)(C)1., (3)(C)2.,
or (3)(C)3. of this rule. The applicable
requirements for a particular storage vessel
depends on the control equipment installed to
meet the requirements of this rule.
1. After installing the control equipment
necessary to comply with paragraph (3)(A)1.
of this rule for permanently affixed roofs and
internal floating roofs, each owner or operator shall—
A. Visually inspect the internal floating roof, the primary seal, and the secondary
seal (if one (1) is in service) prior to filling
the storage vessel with VOL. If there are
holes, tears, or other openings in the primary
seal, the secondary seal, or the seal fabric or
defects in the internal floating roof, or both,
repair the items before filling the storage vessel;
B. For storage vessels equipped with a
liquid-mounted or mechanical shoe primary
seal, visually inspect the internal floating
roof and the primary seal or the secondary
seal (if one (1) is in service) through manholes and roof hatches on the fixed roof at
least once every twelve (12) months after initial fill. If the internal floating roof is not
resting on the surface of the VOL inside the
storage vessel, or if there is liquid accumulated on the roof, or if the seal is detached, or
if there are holes or tears in the seal fabric,
repair the items or empty and remove the
storage vessel from service within forty-five
(45) days. If a failure that is detected during
inspections required in this rule subsection
cannot be repaired within forty-five (45) days
and if the storage vessel cannot be emptied
within forty-five (45) days, the owner or
operator may request a thirty (30)-day extension from the department in the inspection
report described in paragraph (4)(A)2. of this
rule. Such a request for an extension must
document that alternate storage capacity is
unavailable and specify a schedule of actions
the owner or operator will take that will
assure that the control equipment will be
repaired or the storage vessel will be emptied
within thirty (30) days;
C. For storage vessels equipped with
both primary and secondary seals—
(I) Visually inspect the storage vessel as specified in subparagraph (3)(C)1.D.
of this rule at least every five (5) years; or
(II) Visually inspect the storage
vessel
as
specified
in
subparagraph
(3)(C)1.B. of this rule;
D. Visually inspect the internal floating roof, primary seal, secondary seal (if one
(1) is in service), gaskets, slotted membranes, and sleeve seals (if any) each time the
storage vessel is emptied and degassed. If the
internal floating roof has defects, the primary
seal has holes, tears, or other openings in the
seal, or if the seal fabric or the secondary
seal has holes, tears, or other openings in the
seal, or if the seal fabric or the gaskets no
longer close off the liquid surfaces from the
atmosphere, or if the slotted membrane has
more than ten percent (10%) open area,
repair the items as necessary so that none of
the conditions specified in this rule subsection exist before refilling the storage vessel
with VOL. In no event shall inspections conducted in accordance with this provision
occur at intervals greater than ten (10) years
in the case of storage vessels subject to the
annual visual inspection as specified in subparagraph (3)(C)1.B. and part (3)(C)1.C.(II)
of this rule and at intervals no greater than
five (5) years in the case of storage vessels
specified in part (3)(C)1.C.(I) of this rule;
and
E. Notify the department in writing at
least thirty (30) days prior to the filling or
refilling of each storage vessel for which an
inspection is conducted in accordance with
subparagraphs (3)(C)1.A. and (3)(C)1.D. of
this rule to afford the department the opportunity to have an observer present. If the
inspection under subparagraph (3)(C)1.D. of
this rule is not planned and the owner or
operator could not have known about the
inspection thirty (30) days in advance of
refilling the storage vessel, notify the department at least seven (7) days prior to the refilling of the storage vessel. Notification shall be
made by telephone immediately followed by
written documentation demonstrating why
the inspection was unplanned. Alternatively,
this notification including the written documentation may be made in writing and sent
by express mail so that it is received by the
department at least seven (7) days prior to the
refilling.
2. The owner or operator of external
floating roof storage vessels shall—
A. Determine the gap areas and maximum gap widths between the primary seal
and the wall of the storage vessel and between
the secondary seal and the wall of the storage
vessel.
(I) Perform measurements of gaps
between the storage vessel wall and the primary seal (seal gaps) during the hydrostatic
testing of the storage vessel or within sixty
(60) days after the initial fill with VOL and at
least once every five (5) years thereafter.
(II) Perform measurements of gaps
between the storage vessel wall and the secondary seal within sixty (60) days after the
initial fill with VOL and at least once per year
thereafter.
(III) If any source ceases to store
VOL for a period of one (1) year or more,
subsequent introduction of VOL into the storage vessel shall be considered an initial fill
for the purposes of parts (3)(C)2.A.(I) and
(3)(C)2.A.(II) of this rule;
B. Determine gap widths and areas in
the primary and secondary seals individually
according to the following procedures:
(I) Measure seal gaps, if any, at one
(1) or more floating roof levels when the roof
is floating off the roof leg supports;
(II) Measure seal gaps around the
entire circumference of the storage vessel in
each place where a one-eighth inch (1/8") in
diameter uniform probe passes freely without
forcing or binding against seal between the
seal and the wall of the storage vessel and
measure the circumferential distance of each
such location; and
(III) Determine the total surface
area of each gap described in part
(3)(C)2.B.(II) of this rule by using probes of
various widths to measure accurately the
actual distance from the storage vessel wall to
the seal and multiplying each such width by
its respective circumferential distance;
C. Add the gap surface area of each
gap location for the primary seal and the secondary seal individually and divide the sum
for each by the nominal diameter of the storage vessel and compare each ratio to the
respective
standards
in
subparagraph
(3)(C)2.D. of this rule;
D. Make necessary repairs or empty
the storage vessel within forty-five (45) days
after identification in any inspection for seals
not meeting the requirements listed in parts
(3)(C)2.D.(I) and (3)(C)2.D.(II) of this rule.
(I) The accumulated area of gaps
between the storage vessel wall and the
mechanical shoe or liquid-mounted primary
seal shall not exceed one inch (1.0") per foot
of storage vessel diameter, and the width of
any portion of any gap shall not exceed one
and one-half inches (1.5"). There shall be no
holes, tears, or other openings in the shoe,
seal fabric, or seal envelope.
(II) The secondary seal shall meet
the following requirements:
(a) Be installed above the primary seal so that it completely covers the space
between the roof edge and the storage vessel
wall except as provided in part (3)(C)2.B.(III)
of this rule;
(b) The accumulated area of gaps
between the storage vessel wall and the secondary seal used in combination with a
metallic shoe or liquid-mounted primary seal
shall not exceed one inch (1.0") per foot of
storage vessel diameter, and the width of any
portion of any gap shall not exceed one-half
inch (0.5"). There shall be no gaps between
the storage vessel wall and the secondary seal
when used in combination with a vapor
mounted primary seal; and
(c) There shall be no holes,
tears, or other openings in the seal or seal
fabric.
(III) If a failure that is detected during
inspections
required
in
subparagraph
(3)(C)2.A. of this rule cannot be repaired
within forty-five (45) days and if the storage
vessel cannot be emptied within forty-five
(45) days, the owner or operator may request
a thirty (30)-day extension from the department in the inspection report required in subparagraph (3)(C)2.D. of this rule. Such
extension request must include a demonstration of unavailability of alternate storage
capacity and a specification of a schedule that
will assure that the control equipment will be
repaired or the storage vessel will be emptied
as soon as possible;
E. Notify the department thirty (30)
days in advance of any gap measurements
required by subparagraph (3)(C)2.A. of this
rule to afford the department the opportunity
to have an observer present; and
F. Visually inspect the external floating roof, the primary seal, secondary seal,
and fittings each time the storage vessel is
emptied and degassed.
(I) If the external floating roof has
defects, if the primary seal has holes, tears,
or other openings in the seal or the seal fabric, or if the secondary seal has holes, tears,
or other openings in the seal or the seal fabric, repair the items as necessary so that none
of the conditions specified in this rule subsection exist before filling or refilling the storage
vessel with VOL.
(II) For all the inspections required
by subparagraph (3)(C)2.F. of this rule, the
owner or operator shall notify the department
in writing at least thirty (30) days prior to the
filling or refilling of each storage vessel to
afford the department the opportunity to
inspect the storage vessel prior to refilling. If
the inspection under subparagraph (3)(C)2.F.
of this rule is not planned and the owner or
operator could not have known about the
inspection thirty (30) days in advance of
refilling the storage vessel, notify the department at least seven (7) days prior to the refilling of the storage vessel. Notification shall be
made by telephone immediately followed by
written documentation demonstrating why
the inspection was unplanned. Alternatively,
this notification including the written documentation may be sent by express mail so that
it is received by the department at least seven
(7) days prior to the refilling.
3. The owner or operator of each storage
vessel equipped with a closed vent system
and a flare to meet the requirements of paragraph (3)(A)3. of this rule shall meet the
requirements specified in the general control
device requirements of 40 CFR 60.18(e) and
(f), as specified in 10 CSR 10-6.070(3)(A)1.
(4) Reporting and Record Keeping.
(A) After installing control equipment in
accordance with paragraph (3)(A)1. of this
rule for fixed roofs and internal floating
roofs, the owner or operator shall—
1. Keep a record of each inspection performed as required by subparagraphs
(3)(C)1.A., (3)(C)1.B, (3)(C)1.C., and
(3)(C)1.D. of this rule. Each record shall
identify the storage vessel on which the
inspection was performed, contain the date
the storage vessel was inspected, and the
observed condition of each component of the
control equipment including seals, internal
floating, and fittings;
2. If any of the conditions described in
subparagraph (3)(C)1.B. of this rule are
detected during the annual visual inspection,
report to the department within twenty (20)
days after the inspection the identity of the
storage vessel, the nature of the defects, and
the date the storage vessel was emptied or the
nature of and date the repair was made; and
3. After each inspection required by
Specific to the St. Louis Metropolitan Area
subparagraph (3)(C)1.C. of this rule where
tears or holes in the seal or seal fabric, or
defects in the internal floating roof, or other
control equipment defects listed in part
(3)(C)1.C.(II) of this rule are discovered,
report to the department within twenty (20)
days after the inspection the identity of the
storage vessel and the reason it did not meet
the specifications of paragraph (3)(A)1. or
(3)(C)1. of this rule, and list each repair
made.
(B) After installing control equipment in
accordance with paragraph (3)(A)2. of this
rule for external floating roofs, the owner or
operator shall—
1. Within sixty (60) days after performing the seal gap measurements required by
subparagraph (3)(C)2.A. of this rule, furnish
the department with a report that contains the
date of measurement, the raw data obtained
in the measurement, and the calculations of
this rule described in subparagraphs
(3)(C)2.B. and (3)(C)2.C. of this rule;
2. Maintain records of each gap measurement performed under subparagraph
(3)(C)2.B. of this rule. Such records shall
identify the storage vessel in which the measurement was performed and shall contain the
date of measurement, the raw data obtained
in the measurement, and the calculations of
this rule described in subparagraphs
(3)(C)2.B. and (3)(C)2.C. of this rule; and
3. After each seal gap measurement that
detects gaps exceeding the limitations specified by subparagraph (3)(C)2.D. of this rule,
submit a report to the department within
twenty (20) days after the inspection identifying the storage vessel and containing the
information specified in paragraph (4)(B)1.
of this rule and the date the storage vessel was
emptied or the repairs were made and the
date of the repair.
(C) After installing control equipment to
comply with subsection (3)(C) of this rule for
closed vent systems and control device other
than a flare, the owner or operator shall
maintain a record of the measured values of
the parameters monitored in accordance with
the requirements of this rule.
(D) After installing a closed vent system
and flare to comply with subsection (3)(C) of
this rule, the owner or operator shall—
1. Provide the department with a report
containing the measurements recorded under
paragraph (3)(C)3. of this rule within six (6)
months after the initial start-up date;
2. Maintain records of all periods of
operation during which the flare pilot flame
is absent; and
3. Report semiannually all periods
recorded under paragraph (4)(D)2. of this
rule in which the pilot flame was absent.
(E) The owner or operator of each storage
vessel specified in section (1) of this rule
shall maintain readily accessible records of
the dimensions of the storage vessel and an
analysis of the capacity of the storage vessel.
(F) Except as provided in paragraphs
(4)(G)3. and (4)(G)4. of this rule, the owner
or operator of each storage vessel subject to
the requirements in subsection (3)(A) or
(3)(B) of this rule with a design capacity
greater than or equal to forty thousand
(40,000) gallons storing a liquid with a maximum true vapor pressure greater than or
equal to one-half (0.5) psia but less than
three-quarters (0.75) psia shall maintain a
record of the VOL storage, the period of storage, and the maximum true vapor pressure of
the VOL during the respective storage period.
(G) Monitoring Requirements.
1. Except as provided in paragraph
(4)(G)4. of this rule, the owner or operator of
each storage vessel with a design capacity
greater than or equal to forty thousand
(40,000) gallons storing a liquid with a maximum true vapor pressure that is normally
less than three-quarters (0.75) psia shall notify the department within thirty (30) days
when the maximum true vapor pressure of the
liquid exceeds three-quarters (0.75) psia.
2. Available data on the storage temperature may be used to determine the maximum
true vapor pressure.
A. For storage vessels operated above
or below ambient temperatures, the maximum true vapor pressure is calculated based
upon the highest expected calendar-month
average of the storage temperature. For storage vessels operated at ambient temperatures,
the maximum true vapor pressure is calculated based upon the maximum local monthly
average ambient temperature as reported by
the National Weather Service.
B. For other liquids, the vapor pressure shall be determined by an appropriate
test method in section (5) of this rule or calculated by an appropriate method approved
by the department.
3. The owner or operator of each storage
vessel storing a mixture of indeterminate or
variable composition shall be subject to the
following:
A. Prior to the initial filling of the
storage vessel, the maximum true vapor pressure for the range of anticipated liquid compositions to be stored will be determined
using the methods described in paragraph
(4)(G)2. of this rule; and
B. For storage vessels in which the
vapor pressure of the anticipated liquid composition is one-half (0.5) psia or greater but
less than three-quarters (0.75) psia, perform
an initial physical test of the vapor pressure;
a physical test at least once every six (6)
months thereafter is required as determined
by an appropriate test method in section (5)
of this rule.
4. The owner or operator of each storage
vessel equipped with a closed vent system
and control device meeting the specifications
of subsection (3)(A) or (3)(B) of this rule is
exempt from the requirements of paragraphs
(4)(G)1. and (4)(G)2. of this rule.
(H) The owner or operator shall maintain
all records required by this rule section,
except for the records described in subsection
(4)(E) of this rule, on-site for at least five (5)
years. The records described in subsection
(4)(E) of this rule shall be kept on-site for the
life of the source. The records required by
this rule shall be made available to the department immediately upon request.
(5) Test Methods.
(A) American Petroleum Institute (API)
Bulletin 2517, Evaporation Loss From
External Floating Roof Tanks, Second
Edition, as published by API, February 1980.
This publication is hereby incorporated by
reference in this rule. Copies can be obtained
from API, 1220 L Street NW, Washington,
DC 20005. This rule does not incorporate
any subsequent amendments or additions.
(B) The following documents are published
by the American Society for Testing and
Materials (ASTM) and incorporated by reference in this rule. Copies can be obtained
from ASTM International, 100 Barr Harbor
Drive, PO Box C700, West Conshohocken,
PA 19428-2959. This rule does not incorporate any subsequent amendments or additions:
1. ASTM D323-82 or 94 Standard Test
Method for Vapor Pressure of Petroleum
Products (Reid Method); and
2. ASTM D2879-83, 96, or 97 Standard
Test Method for Vapor Pressure-Temperature
Relationship and Initial Decomposition
Temperature of Liquids by Isoteniscope;
(C) The following ASTMs as specified in
10 CSR 10-6.040(36):
1. ASTM D4953 Standard Test Method
for Vapor Pressure of Gasoline and GasolineOxygenate Blends (Dry Method); and
2. ASTM D5191 Standard Test Method
for Vapor Pressure of Petroleum Products
(Mini Method);
(D) The following test methods as specified in 10 CSR 10-6.030(22):
1. Test Methods 1 and 2 (40 CFR 60,
Appendix A) for determining flow rates, as
necessary;
2. Test Method 18 (40 CFR 60,
Appendix A) for determining gaseous organic
compound emissions by gas chromatography;
3. Test Method 21 (40 CFR 60,
Appendix A) for determination of volatile
organic compound leaks;
4. Test Method 22 (40 CFR 60,
Appendix A) for visual determination of fugitive emissions from material sources and
smoke emissions from flares;
5. Test Method 25 (40 CFR 60,
Appendix A) for determining total gaseous
nonmethane organic emissions as carbon; and
6. Test Methods 25A or 25B (40 CFR
60, Appendix A) for determining total
gaseous organic concentrations using flame
ionization or nondispersive infrared analysis;
(E) Test method described in 40 CFR
60.113(a)(ii) as specified in 10 CSR 106.070(3)(A)1. for measurement of storage
tank seal gap;
(F) Other method approved by the director.
AUTHORITY: section 643.050, RSMo 2016.*
Original rule filed July 15, 1999, effective
Feb. 29, 2000. Amended: Filed May 9, 2018,
effective Feb. 28, 2019. Amended: Filed Oct.
8, 2019, effective July 30, 2020.
*Original authority: 643.050, RSMo 1965, amended
1972, 1992, 1993, 1995, 2011.