10 CSR 20-8.210
Supplemental Treatment
PURPOSE: This rule specifies the minimum standards for the design of supplemental treatment processes that are part of wastewater collection and treatment systems. This rule is to be used
with rules 10 CSR 20-8.110 through 10 CSR 20-8.210. It does not
address all aspects of design, and the design engineer may refer to
other appropriate reference materials so long as these minimum
standards set forth in this rule are met.
Editor’s Note: The secretary of state has determined that the publication of this rule in its entirety would be unduly cumbersome
or expensive. The entire text of the material referenced has been
filed with the secretary of state. This material may be found at the
Office of the Secretary of State or at the headquarters of the agency
and is available to any interested person at a cost established by
state law.
(1) Applicability. Wastewater systems that utilize supplemental
treatment shall be designed based on criteria contained in this
rule, published standards, applicable federal and state requirements, standard textbooks, current technical literature and applicable safety standards. In the event of any conflict between
the above criteria, the requirement in this rule shall prevail.
(A) This rule shall not apply to treatment units covered in 10
CSR 20-8.300.
(B) This rule shall not apply to treatment units covered in 10
CSR 20-8.500.
(2) Polishing Reactors.
(A) Design. The process shall—
1. Provide a minimum hydraulic retention time of three
(3) hours;
2. Be based on actual reactor influent characteristics;
3. Be based on Biochemical Oxygen Demand loading rate
of forty-eight pounds per one thousand cubic feet per day (48
lbs BOD/1,000 cf/day) or less;
4. Be sized using less than two tenths a pound TKN per one
thousand square feet per day (0.2 lbs TKN/1,000 ft2/day) when
nitrifying;
5. Provide sufficient alkalinity with a minimum residual
of fifty milligrams per liter (50 mg/L) in the effluent or include
chemical treatment;
6. Include cold weather provisions, such as heaters, insulated covers, installation of temperature controlled enclosures
for above-ground components to prevent freezing and to ensure ammonia removal; and
7. Provide a blower malfunction alarm able to notify the
operator of alarm activations through audio-visual means.
(3) Filtration.
(A) Filtration systems shall be preceded with additional process, such as chemical coagulation and sedimentation or other
acceptable process, when:
1. Permit requirements for total suspended solids (TSS) are
less than ten milligrams per liter (10 mg/L);
2. Effluent quality is expected to fluctuate significantly;
3. Significant amounts of algae are present; or
4. The manufacturer recommends an additional process.
(B) General Design.
1. Filtration systems shall have:
A. Convenient access to all components and the media
surface for inspection and maintenance without taking other
units out of service;
B. Enclosed controls and heating and ventilation equipment to control humidity; and
C. The capacity to process the design average flow to the
filters with the largest unit out of service utilizing a minimum
of two (2) units.
2. Flocculation. For filtration systems requiring coagulation and flocculation prior to the filtration, the flocculation
system shall:
A. Include chemical feed equipment to meet the system’s anticipated peak design flow and the ability to proportion chemical feed rates; and
B. Ensure the rapid dispersion and mixing of chemicals
throughout the wastewater by providing mechanical or in-line
static mixers.
(C) Deep bed filters.
1. The design of manifold type filtrate collection or
underdrain systems shall:
A. Minimize loss of head in the manifold and baffles;
B. Provide the ratio of the area of the underdrain orifices
to the entire surface area of the filter media at about three
one-thousandths (0.003);
C. Provide the total cross-sectional area of the laterals at
about twice the area of the final openings; and
D. Provide a manifold that has a minimum cross sectional area that is one and one half (1.5) times the total area of
the laterals.
2. All rotary surface wash devices shall provide adequate
surface wash water to provide one half to one gallon per minute per square foot (0.5-1.0 gpm/ sq ft) of filter area.
(D) Shallow bed filters. The shallow bed filter shall:
1. Comply with the manufacturer’s recommendations at
average design flow;
2. Provide multiple unit operations to allow for continuous
operability and operational variability;
3. Consist of a series of up to eight inch (8") filter increments having a minimum total media depth of eleven inches
(11"), if using filter media except for sand media.
4. Have an effective size in the range of four-tenths millimeter to sixty-five hundredths millimeters (0.40 mm-0.65 mm)
and a uniformity coefficient of one and one half (1.5) or less, if
utilizing sand media;
5. Include inlet ports located throughout the length of the
filter.
6. Provide an underdrainage system along the entire
length of the filter so that filter effluent is uniformly withdrawn
without clogging outlet openings.
7. Have a traveling bridge mechanism which—
A. Provides support and access to the backwash pumps
and equipment;
B. Is constructed of corrosion resistant materials;
C. Provides for consistent tracking of the bridge;
D. Provides support of the power cords; and
E. Initiates a backwash cycle automatically when a preset head loss through the filter media occurs.
(E) Cloth/Disc Filters.
1. Media Design. The media shall:
A. Have an average pore size of no larger than thirty (30)
microns;
B. Follow the manufacturer’s recommendations; and
C. Be chemical-resistant if the filter will be exposed to
chemicals, such as chlorine or disinfectants.
2. Filtration Rates and Hydraulics. The design shall—
A. Base the filtration rate on the effective submerged
surface area of the media and provide a maximum filtration
rate for peak flow of not more than six and one half gallons
per minute per square foot (6.5 gpm/sq ft) of submerged cloth
media; and
B. Be able to treat the design flow rate with one (1) filter
unit in backwash mode.
(4) Microscreening.
(A) Screen Material. The microfabric shall be a material
demonstrated to be durable through long-term performance
data.
(B) Backwash. All backwash shall be recycled for treatment.
(5) In-stream Diffusers.
(A) General.
1. The mixing zone shall not encroach on a drinking water
intake, recreation area, or sensitive habitat, overlap the next
downstream outfall, or occlude a downstream tributary.
2. Diffuser installation requires notification and an Army
Corps of Engineers permit.
(B) Diffuser Design Criteria.
1. The pipeline shall be contained within approved property boundaries or easements.
2. Maximum port velocity shall not exceed fifteen feet per
second (15 fps).
AUTHORITY: section 644.026, RSMo 2016.* Original rule filed Aug.
10, 1978, effective March 11, 1979. Amended: Filed June 15, 2018,
effective Feb. 28, 2019.
*Original authority: 644.026, RSMo 1972, amended 1973, 1987, 1993.