10 CSR 60-15.030
Description of Corrosion Control Treatment Requirements
PURPOSE: This rule describes the corrosion
control treatment requirements which are
applicable to all water systems under 10 CSR
60-15.020.
(1) Based upon the results of lead and copper
tap monitoring and water quality parameter
monitoring, small- (serving fewer than three
thousand three hundred (3,300) persons) and
medium-size (serving three thousand three
hundred one to fifty thousand (3,301–50,000)
persons) water systems exceeding the lead or
copper action level shall recommend installation of one (1) or more of the corrosion control treatments listed in subsection (3)(A),
which the system believes constitutes optimal
corrosion control for that system. The department may require the system to conduct additional water quality parameter monitoring in
accordance with 10 CSR 60-15.080(2) and
perform corrosion control studies as
described in this rule to assist the department
in reviewing the system’s recommendations.
(2) The department may require any small- or
medium-sized systems that exceed the lead or
copper action level to perform corrosion control studies under section (3) of this rule to
identify optimal corrosion control treatment
for the system.
(3) Performance of Corrosion Control
Studies.
(A) Any public water system performing
corrosion control studies shall evaluate the
effectiveness of each of the following treatments and, if appropriate, combinations of
the following treatments to identify the optimal corrosion control treatment for that system:
1. Alkalinity and pH adjustment;
2. Calcium hardness adjustment; and
3. The addition of a phosphate or silicate based corrosion inhibitor at a concentration sufficient to maintain an effective residual concentration in all test tap samples.
(B) The water system shall evaluate each of
the corrosion control treatments using either
pipe rig/loop tests, metal coupon tests, partial-system tests or analyses based on documented analogous treatments with other systems of similar size, water chemistry and distribution system configuration.
(C) The water system shall measure the
following water quality parameters in any
tests conducted under this section before and
after evaluating the corrosion control treatments listed in paragraph (3)(A)1. of this
rule:
1. Lead;
2. Copper;
3. pH;
4. Alkalinity;
5. Calcium;
6. Conductivity;
7. Orthophosphate (when an inhibitor
containing a phosphate compound is used);
8. Silicate (when an inhibitor containing
a silicate compound is used); and
9. Water temperature.
(D) The water system shall identify all
chemical or physical constraints that limit or
prohibit the use of a particular corrosion control treatment and document these constraints
with at least one (1) of the following:
1. Data and documentation showing that
a particular corrosion control treatment has
adversely affected other water treatment processes when used by another water system
with comparable water quality characteristics; or
2. Data and documentation demonstrating that the water system has previously
attempted to evaluate a particular corrosion
control treatment and has found that the treatment is ineffective or adversely affects other
water quality treatment processes.
(E) The water system shall evaluate the
effect of the chemicals used for corrosion
control treatment on other water quality treatment processes.
(F) On the basis of an analysis of the data
generated during each evaluation, the water
system shall recommend to the department,
in writing, the treatment option that the corrosion control studies indicate constitutes
optimal corrosion control treatment for that
system. The water system shall provide a
rationale for its recommendation along with
all supporting documentation specified in this
section.
(4) Based upon consideration of available
information including, where applicable,
studies performed under section (3) of this
rule and a system’s recommended treatment
alternative, the department shall either
approve the corrosion control treatment
option recommended by the system or designate alternative corrosion control treatment(s)
from among those listed in subsection (3)(A)
of this rule. When designating optimal treatment, the department shall consider the
effects that additional corrosion control treatment will have on the water quality parameters and on other water quality treatment processes.
(5) The department, in writing, shall notify
the system of its decision on optimal corrosion control treatment and explain the basis
for this determination. If the department
requests additional information to aid its
review, the water system shall provide the
information.
(6) Each system shall properly install and
operate throughout its distribution system the
optimal corrosion control treatment designated by the department.
(7) The department shall evaluate the results
of all lead and copper tap samples and water
quality parameter samples submitted by the
water system and determine whether the system has properly installed and operated the
optimal corrosion control treatment designated by the department. Upon reviewing the
results of tap water and water quality parameter monitoring by the system, both before
and after the system installs optimal corrosion control treatment, the department shall
designate—
(A) A minimum value or a range of values
for pH measured at each entry point to the
distribution system;
(B) A minimum pH value measured in all
tap samples. That value shall be equal to or
greater than 7.0, unless the department determines that meeting a pH level of 7.0 is not
technologically feasible or is not necessary
for the system to optimize corrosion control;
(C) If a corrosion inhibitor is used, a minimum concentration or a range of concentrations for the inhibitor measured at each entry
point to the distribution system and in all tap
samples, that the department determines is
necessary to form a passivating film on the
interior walls of the pipes of the distribution
system;
(D) If alkalinity is adjusted as part of optimal corrosion control treatment, a minimum
concentration or a range of concentrations for
alkalinity, measured at each entry point to the
distribution system and in all tap samples;
(E) If calcium carbonate stabilization is
used as part of corrosion control, a minimum
concentration or a range of concentrations for
calcium, measured in all tap samples.
(F) The values for the applicable water
quality control parameters listed in this section shall be those that the department determines to reflect optimal corrosion control
treatment for the system. The department
may designate values for additional water
quality control parameters determined by the
department to reflect optimal corrosion control for the system. The department shall
notify the system, in writing, of these determinations and explain the basis for its decisions.
(8) All systems optimizing corrosion control
shall continue to operate and maintain optimal corrosion control treatment, including
maintaining water quality parameters at or
above minimum values or within ranges designated by the department under section (7)
of this rule for all samples collected under 10
CSR 60-15.080(4)–(6). Compliance with this
section shall be determined every six (6)
months, as specified under 10 CSR 6015.080(4). A water system is out of compliance with the requirements of this section (8)
for a six (6)-month period if it has excursions
for any department-specified parameter on
more than nine (9) days during the period. An
excursion occurs whenever the daily value for
one (1) or more of the water quality parameters measured at a sampling location is below
the minimum value or outside the range designated by the department. Daily values are
calculated as follows. The department shall
have discretion to delete results of obvious
sampling errors from this calculation.
(A) On days when more than one (1) measurement for the water quality parameter is
collected at the sampling location, the daily
value shall be the average of all results collected during the day regardless of whether
they are collected through continuous monitoring, grab sampling, or a combination of
both.
(B) On days when only one (1) measurement for the water quality parameter is collected at the sampling location, the daily
value shall be the result of that measurement.
(C) On days when no measurement is collected for the water quality parameter at the
sampling location, the daily value shall be the
daily value calculated on the most recent day
on which the water quality parameter was
measured at the sample site.
(9) The department, upon its own initiative or
in response to a request by a water system or
other interested party, may modify its determination of the optimal corrosion control
treatment or optimal water quality control
parameters. A request for modification by a
system or other interested party shall be in
writing, explain why the modification is
appropriate and provide supporting documentation. The department may modify its determination where it concludes that the change
is necessary to ensure that the system continues to optimize corrosion control treatment.
A revised determination shall be made in
writing, setting forth the new treatment
requirements, explaining the basis for the
department’s decision and providing an
implementation schedule for completing the
treatment modifications.
AUTHORITY: section 640.100, RSMo 2000.*
Original rule filed Aug. 4, 1992, effective
May 6, 1993. Amended: Filed Aug. 14, 2001,
effective April 30, 2002.
*Original authority: 640.100, RSMo 1939, amended 1978,
1981, 1982, 1988, 1989, 1992, 1993, 1995, 1996, 1998,
1999.