10 CSR 60-4.055
Disinfection Requirements
PURPOSE: This rule establishes minimum
disinfectant levels and treatment requirements
to assure the inactivation and removal of
pathogenic organisms.
PUBLISHER’S NOTE: The secretary of state
has determined that the publication of the
entire text of the material which is incorporated by reference as a portion of this rule
would be unduly cumbersome or expensive.
This material as incorporated by reference in
this rule shall be maintained by the agency at
its headquarters and shall be made available
to the public for inspection and copying at no
more than the actual cost of reproduction.
This note applies only to the reference material. The entire text of the rule is printed
here.
(1) The requirements of this rule apply to primary community and noncommunity public
water systems that the department has
required to disinfect and to secondary systems with a source of water from a primary
water system that the department has required
to disinfect, even if the water is obtained
through another secondary system.
(A) Water systems using water obtained in
whole or in part from a source determined by
the department to be surface or ground water
under the direct influence of surface water
must install or construct facilities to provide
conventional filtration treatment as a required
treatment technique within eighteen (18)
months of the determination.
(B) Any water system that the department
determines to be a groundwater system under
the direct influence of surface water may
appeal the decision by notifying the department in writing. The appeal must be accompanied by a report prepared by an engineer
that confirms that the water system’s groundwater source is not directly influenced by surface water. The report must be supported by
analytical data prepared by a laboratory that
is acceptable to the department. Source sampling must be accomplished during the period the source is most susceptible to surface
water influence. The department’s approval
of the report will result in the water system’s
source being redefined as groundwater not
under the direct influence of surface water.
(C) If at any time in the department’s opinion, the quality of a water source appears to
Second stage filtration
Monthly verification that 100%
of flow was filtered through both
stages and that first stage was
preceded by coagulation step
Within 10 days following the month in
which monitoring was conducted,
beginning on the applicable treatment
compliance date in section (12) of this
rule
Slow sand filtration (as
secondary filter)
Monthly verification that both a
slow sand filter and a preceding
separate stage of filtration
treated 100% of flow from
surface water and ground water
under the direct influence of
surface water sources
Within 10 days following the month in
which monitoring was conducted,
beginning on the applicable treatment
compliance date in section (12) of this
rule
Chlorine dioxide
Summary of CT values for each
day as described in section (18)
of this rule
Within 10 days following the month in
which monitoring was conducted,
beginning on the applicable treatment
compliance date in section (12) of this
rule
Ozone
Summary of CT values for each
day as described in section (18)
of this rule
Within 10 days following the month in
which monitoring was conducted,
beginning on the applicable treatment
compliance date in section (12) of this
rule
UV
Validation test results
demonstrating operating
conditions that achieve required
UV dose
No later than the applicable treatment
compliance date in section (12) of this
rule
Monthly report summarizing the
percentage of water entering the
distribution system that was not
treated by UV reactors operating
within validated conditions for
the required dose specified in
subsection (18)(D) of this rule
Within 10 days following the month in
which monitoring was conducted,
beginning on the applicable treatment
compliance date in section (12) of this
rule
have changed to be under the direct influence
of surface water, the water system must submit, at the department’s written request, an
engineer-prepared report that describes the
current condition of the water source. If a
report is not submitted, the source will be
reclassified as groundwater supply under the
direct influence of surface water.
(D) The department reserves the authority
to make the final determination of whether or
not a source is defined as groundwater under
the direct influence of surface water.
(E) Primary systems which use water
obtained from groundwater not under the
direct influence of surface water and which
the department requires to disinfect and secondary public water systems do not have to
meet the requirements of section (2) of this
rule but may be required to provide disinfection detention as deemed necessary by the
department. These systems also do not have
to submit reports to the department as
required by 10 CSR 60-7.010(4) but must
maintain the information on file at the system
treatment plant or office.
(2) Contact Time and Removal Credit.
(A) Any water system providing required
treatment, and existing water systems practicing conventional filtration treatment on
February 6, 1992, will be credited with
99.68 percent (2.5 log) Giardia lamblia cyst
removal and 99.0 percent (2.0 log) virus
removal, excluding the disinfection process,
provided that they meet the turbidity maximum contaminant levels in 10 CSR 60-4.050.
A system may request additional credit for
treatment process removal or inactivation of
Giardia lamblia cysts and viruses by submitting a report prepared by an engineer to the
department including studies of Giardia cyst
and virus removal or inactivation. The
department reserves the authority to make the
final determination of removal credit.
(B) The residual disinfectant concentration
(C) disinfectant contact time (T) values in the
Missouri Guidance Manual for Surface Water
System Treatment Requirements, 1992, must
be used for determining the percentage of
Giardia lamblia cyst and virus removal or
inactivation by disinfection.
(C) The percentage of removal and inactivation of Giardia lamblia cysts and viruses
will be determined as the sum of the percent
removals and inactivations of the individual
treatment and disinfection processes. The
percent removal and inactivation of Giardia
lamblia cysts must be at least 99.9 percent
(3.0 log) and of viruses must be 99.99 percent (4.0 log).
(D) Disinfectant contact time must be determined for each system by evaluations performed as specified in the Missouri Guidance
Manual for Surface Water System Treatment
Requirements, 1992, which is incorporated
by reference. Results of the evaluations,
including the determined disinfectant contact
times, must be submitted to the department
for review. The evaluation must be submitted
within one (1) year of the date that the system
is covered by the requirements of this rule,
except that new water treatment facilities will
not be issued a Final Approval of Construction
under 10 CSR 60-3.010 until disinfection contact times are determined and submitted to the
department.
(3) For any water system adding a disinfectant, only free available chlorine or chloramines will be accepted as the disinfectant
entering the distribution system. The residual
disinfectant concentration in the water entering the distribution system cannot be less than
0.5 milligrams per liter (mg/L) free available
chlorine or 1.0 mg/L chloramines for more
than four (4) hours.
(A) Systems using chloramines as the disinfectant residual entering the distribution
system must add and mix the chlorine prior to
the addition of ammonia.
(B) At the department’s discretion, any
system may be required to provide breakpoint
chlorination or to provide operational test
data and other information that the department may require to demonstrate that the system daily meets all of the requirements of
section (2) of this rule and all of the other
requirements of this section.
(C) At least one (1) application point for
chlorine or chloramines must be prior to filtration with a residual maintained through the
filters.
(D) If at any time the disinfectant residual
entering the distribution system falls below
the levels established in this section, the system must notify the department as soon as
possible but no later than by the end of the
next business day. The system must notify the
department by the end of the next business
day whether or not the disinfectant residual
was restored to the levels established in this
section within four (4) hours. The department
may require public notice for continuing or
persistent violations of this requirement.
(E) A residual disinfectant concentration in
the water entering the distribution system of
less than 0.2 mg/L for at least four (4) hours
is a treatment technique violation which
requires public notice pursuant to 10 CSR 608.010.
(F) The frequency of sampling shall be as
set forth in 10 CSR 60-4.080(3).
(4) The residual disinfectant concentration in
the distribution system measured as total
chlorine or combined chlorine cannot be less
than 0.2 mg/L in more than five percent (5%)
of the samples each month for any two (2)
consecutive months that the system supplies
water to the public.
(A) Heterotrophic plate count may be used
in lieu of or as a supplement to residual disinfectant concentration analysis.
(B) Water in the distribution system with a
heterotrophic bacteria concentration less than
or equal to five hundred (500) colonies per
milliliter is deemed to have 0.2 mg/L residual disinfectant concentration for the purpose
of determining compliance with this rule.
(C) Water in the distribution system with a
heterotrophic bacteria concentration of
greater than five hundred (>500) colonies
per milliliter is deemed to have less than 0.2
mg/L residual disinfectant concentration for
the purpose of compliance with this rule.
(D) Failure to maintain the minimum residual disinfectant concentration required in this
rule is a violation of a treatment technique
which requires public notification as specified in 10 CSR 60-8.010.
(E) Public water systems that use chlorine
or chloramines must measure the residual
disinfectant level in the distribution system at
the same point in the distribution system and
at the same time as total coliforms are sampled, as specified in 10 CSR 60-4.022(4)-(8).
Failure to comply with this subsection is a
monitoring violation which requires public
notification as specified in 10 CSR 60-8.010.
(5) Maximum Residual Disinfectant Levels.
(A) Maximum residual disinfectant levels
(MRDL) applicable to all community and
nontransient noncommunity water systems
using chlorine, chloramines or chlorine dioxide and to all transient noncommunity water
systems using chlorine dioxide are—
Disinfectant Residual
MRDL (mg/L)
Chlorine
4.0 (as Cl2)
Chloramines
4.0 (as Cl2)
Chlorine dioxide
0.8 (as ClO2)
(B) Control of Disinfectant Residuals. For
chlorine and chloramines, a public water system is in compliance with the MRDL when
the running annual average of monthly averages of samples taken in the distribution system, computed quarterly, is less than or equal
to the MRDL. For chlorine dioxide, a public
water system (PWS) is in compliance with the
MRDL when daily samples are taken at the
entrance to the distribution system and no two
(2) consecutive daily samples exceed the
MRDL. MRDLs are enforceable in the same
manner as maximum contaminant levels.
Notwithstanding the MRDLs, systems may
increase residual disinfectant levels in the distribution system of chlorine or chloramines
(but not chlorine dioxide) to a level and for a
time necessary to protect public health, to
address specific microbiological contamination problems caused by circumstances such
as, but not limited to, distribution line breaks,
storm run-off events, source water contamination events, or cross-connection events.
(6) Enhanced Disinfection Requirements.
(A) In addition to the requirements in sections (1)–(4) of this rule, surface water and
groundwater under the direct influence of
surface water systems must comply with the
requirements in this section.
(B) General Requirements.
1. This section (6) establishes or extends
treatment technique requirements in lieu of
maximum contaminant levels for the following
contaminants: Giardia lamblia, viruses, heterotrophic plate count bacteria, Legionella,
Cryptosporidium, and turbidity. Each surface
water and groundwater under the direct influence of surface water system must provide
treatment of its source water that complies
with these treatment technique requirements
and are in addition to those identified in sections (1)–(4) of this rule. The treatment technique requirements consist of installing and
properly operating water treatment processes
which reliably achieve:
A. At least ninety-nine percent (99%)
(2-log) removal of Cryptosporidium between
a point where the raw water is not subject to
recontamination by surface water runoff and
a point downstream before or at the first customer; and
B. Compliance with the profiling and
benchmark requirements under the provisions
of subsection (6)(C) of this rule.
2. A public water system subject to the
requirements of this section (6) is in compliance with the requirements of paragraph
(6)(B)1. of this rule if it meets the applicable
filtration requirements in 10 CSR 60-4.050
and the disinfection requirements in sections
(2)–(4) and subsection (6)(C) of this rule.
(C)
Disinfection
Profiling
and
Benchmarking.
1. Disinfection profile. A disinfection
profile is a summary of Giardia lamblia inactivation through the treatment plant measured
through the course of a year. A public water
system subject to the requirements of this section (6) must determine its total trihalomethanes (TTHM) annual average and its
HAA5 annual average. The annual average is
the arithmetic average of the quarterly averages of four (4) consecutive quarters of monitoring. If the annual average exceeds the levels
in subparagraph (6)(C)1.D. then the requirements in paragraph (6)(C)2. apply.
A. The TTHM annual average must
be the annual average during the same period
as is used for the HAA5 annual average.
B. The HAA5 annual average must be
the annual average during the same period as
is used for the TTHM annual average.
(I) Those systems that have collected four (4) quarters of HAA5 occurrence data
that meets the routine monitoring sample
number and location requirements for TTHM
in 10 CSR 60-4.094 may use those data to
determine whether the requirements of this
section apply.
(II) Those systems that did not collect four (4) quarters of HAA5 occurrence
data that meets the provisions of part
(6)(C)1.B.(I) of this rule by March 31, 2000
must either:
(a) Conduct monitoring for
HAA5 that meets the routine monitoring
sample number and location requirements for
TTHM in 10 CSR 60-4.094 to determine the
HAA5 annual average and whether the
requirements of paragraph (6)(C)2. of this
rule apply; or
(b) Comply with all other provisions of this section as if the HAA5 monitoring had been conducted and the results
required compliance with paragraph (6)(C)2.
of this rule.
C. The system must submit data to the
department on the schedule required by the
department.
D. Any system having either a TTHM
annual average greater than or equal to 0.064
mg/L or an HAA5 annual average greater
than or equal to 0.048 mg/L during the period identified in subparagraphs (6)(C)1.A.
and B. of this rule must comply with paragraph (6)(C)2. of this rule.
2. Disinfection profiling requirements
and compliance dates vary depending on system size. Surface water and groundwater
under the direct influence of surface water
systems serving a population of more than ten
thousand (10,000) must monitor profiling
data according to subparagraph (6)(C)2.B.
through (6)(C)2.C. Surface water and
groundwater under the direct influence of
surface water systems serving a population of
less than ten thousand (10,000) must monitor
profiling data according to subparagraph
(6)(C)2.D.
A. Any system that meets the criteria
in subparagraph (6)(C)1.D. of this rule must
develop a disinfection profile of its disinfection practice for a period of up to three (3)
years.
B. The system must monitor daily for
a period of twelve (12) consecutive calendar
months to determine the total logs of inactivation for each day of operation, based on the
CT99.9 values in Tables 1 through 8 of the
Missouri Guidance Manual for Surface Water
System Treatment Requirements, 1992, as
appropriate, through the entire treatment
plant. This system must begin this monitoring
when requested by the department. As a minimum, the system with a single point of disinfectant application prior to entrance to the
distribution system must conduct the monitoring set forth in this subparagraph
(6)(C)2.B. A system with more than one (1)
point of disinfectant application must conduct
this monitoring for each disinfection segment. The system must monitor the parameters necessary to determine the total inactivation ratio, using analytical methods in 10
CSR 60-5.010, as follows:
(I) The temperature of the disinfected water must be measured once per day
at each residual disinfectant concentration
sampling point during peak hourly flow;
(II) If the system uses chlorine, the
pH of the disinfected water must be measured
once per day at each chlorine residual disinfectant concentration sampling point during
peak hourly flow;
(III) The disinfectant contact
time(s) must be determined for each day during peak hourly flow; and
(IV) The residual disinfectant concentration(s) of the water before or at the first
customer and prior to each additional point of
disinfection must be measured each day during peak hourly flow.
C. In lieu of the monitoring conducted under the provisions of subparagraph
(6)(C)2.B. of this rule to develop the disinfection profile the system may elect to meet
the requirements of part (6)(C)2.C.(I) of this
rule. In addition to the monitoring conducted
under the provisions of subparagraph
(6)(C)2.B. of this rule to develop the disinfection profile, the system may elect to meet
the requirements of part (6)(C)2.C.(II) of this
rule.
(I) A PWS that has three (3) years of
existing operational data may submit those
data, a profile generated using those data, and
a request that the department approve use of
those data in lieu of monitoring under the provisions of paragraph (6)(C)2. of this rule. The
department must determine whether these
operational data are substantially equivalent to
data collected under the provisions of subparagraph (6)(C)2.B. of this rule. These data must
also be representative of Giardia lamblia inactivation through the entire treatment plant and
not just of certain treatment segments. Until
the department approves this request, the system is required to conduct monitoring under
the provisions of subparagraph (6)(C)2.B. of
this rule.
(II) In addition to the disinfection
profile
generated
under
subparagraph
(6)(C)2.B. of this rule, a PWS that has existing operational data may use those data to
develop a disinfection profile for additional
years. Such systems may use these additional
yearly disinfection profiles to develop a
benchmark under the provisions of paragraph
(6)(C)3. of this rule. The department will
determine whether these operational data are
substantially equivalent to data collected
under the provisions of subparagraph
(6)(C)2.B. of this rule. These data must also
be representative of inactivation through the
entire treatment plant and not just of certain
treatment segments.
D. The system must monitor once per
week on the same calendar day, for a period
of twelve (12) consecutive calendar months,
to determine the total logs of inactivation for
each week of operation, based on the CT99.9
values in Tables 1 through 8 of the Missouri
Guidance Manual for Surface Water System
Treatment Requirements, 1992, as appropriate, through the entire treatment plant. As a
minimum, the system with a single point of
disinfectant application prior to entrance to
the distribution system must conduct the
monitoring set forth in this subparagraph. A
system with more than one (1) point of disinfectant application must conduct this monitoring for each disinfection segment. The
system must monitor the parameters necessary to determine the total inactivation ratio,
using analytical methods in 10 CSR 60-5.010,
as follows:
(I) The temperature of the disinfected water must be measured at each residual disinfectant concentration sampling point
during peak hourly flow;
(II) If the system uses chlorine, the
pH of the disinfected water must be measured
at each chlorine residual disinfectant concentration sampling point during peak hourly
flow;
(III) The disinfectant contact time(s)
must be determined during peak hourly flow;
and
(IV) The residual disinfectant concentration(s) of the water before or at the first
customer and prior to each additional point of
disinfection must be measured during peak
hourly flow.
E. The system must calculate the total
inactivation ratio as follows:
(I) The system may determine the
total inactivation ratio for the disinfection
segment based on either of the following
methods:
(a) Determine one (1) inactivation ratio (CTcalc/CT99.9) before or at the
first customer during peak hourly flow; or
(b)
Determine
successive
(CTcalc/CT99.9) values, representing sequential inactivation ratios, between the point of
disinfectant application and a point before or
at the first customer during peak hourly flow.
Under this alternative, the system must calculate the total inactivation ratio by determining (CTcalc/CT99.9) for each sequence and
then adding the (CTcalc/CT99.9) values
together to determine ((CTcalc/CT99.9));
and
(II) The system must determine the
total logs of inactivation by multiplying the
value calculated in part (6)(C)2.D.(I) of this
rule by three (3.0).
F. A system that uses either chloramines or ozone for primary disinfection
must also calculate the logs of inactivation for
viruses using a method identified in the United
States Environmental Protection Agency’s
Office of Water document, Alternative
Disinfectants and Oxidants Guidance Manual,
Volume 99 Issue 14 of EPA 815-R, published
April 1999. This document is incorporated by
reference without any later amendments or
modifications. To obtain a copy, contact the
U.S. Government Printing Office at 732
North Capitol Street NW, Washington, D.C.
20401, toll free (866)512-1800 or by visiting
https://bookstore.gpo.gov.
G. The system must retain disinfection profile data in graphic form, as a spreadsheet, or in some other format acceptable to
the department for review as part of sanitary
surveys conducted by the department.
3. Disinfection benchmarking.
A. Any system required to develop a
disinfection profile under the provisions of
paragraphs (6)(C)1. and 2. of this rule and
that decides to make a significant change to
its disinfection practice must consult with the
department in writing prior to making such
change. Significant changes to disinfection
practice are:
(I) Changes to the point of disinfection;
(II) Changes to the disinfectant(s)
used in the treatment plant;
(III) Changes to the disinfection
process; and
(IV) Any other modification identified by the department.
B. Any system that is modifying its
disinfection practice must calculate its disinfection benchmark using one (1) of the following procedures:
(I) For each year of profiling data
collected and calculated under paragraph
(6)(C)2. of this rule, the system must determine the lowest average monthly Giardia
lamblia inactivation in each year of profiling
data. The system must determine the average
Giardia lamblia inactivation for each calendar month for each year of profiling data by
dividing the sum of Giardia lamblia inactivation by the number of values calculated for
that month; or
(II) The disinfection benchmark is
the lowest monthly average value (for systems
with one (1) year of profiling data) or average
of lowest monthly average values (for systems
with more than one (1) year of profiling data)
of the monthly logs of Giardia lamblia inactivation in each year of profiling data.
C. A system that uses either chloramines or ozone for primary disinfection
must also calculate the disinfection benchmark for viruses using a method approved by
the department.
D. The system must submit the following information to the department as part
of its consultation process:
(I) A description of the proposed
change;
(II) The disinfection profile for
Giardia lamblia (and, if necessary, viruses)
under paragraph (6)(C)2. of this rule and
benchmark as required by subparagraph
(6)(C)3.B. of this rule; and
(III) An analysis of how the proposed change will affect the current levels of
disinfection.
(D) Filtration Sampling Requirements. A
public water system subject to the requirements of this section (6) that provides conventional filtration treatment must conduct
continuous monitoring of turbidity for each
individual filter as indicated in 10 CSR 604.050(2)(D)1.
AUTHORITY: section 640.100, RSMo 2016.*
Original rule filed July 12, 1991, effective
Feb. 6, 1992. Amended: Filed Feb. 1, 1996,
effective Oct. 30, 1996. Amended: Filed Dec.
15, 1999, effective Sept. 1, 2000. Amended:
Filed March 17, 2003, effective Nov. 30,
2003. Amended: Filed Aug. 12, 2015, effective March 30, 2016. Amended: Filed June
13, 2018, effective Feb. 28, 2019.
*Original authority: 640.100, RSMo 1939, amended 1978,
1981, 1982, 1988, 1989, 1992, 1993, 1995, 1996, 1998,
1999, 2002, 2006, 2012, 2014.