2 CSR 90-60.060
Approved Monumentation
PURPOSE: This rule prescribes the approved type of monumentation
to be used on property boundary surveys.
(1) The professional land surveyor shall select a type of
monument providing a degree of permanency consistent
with that of the adjacent terrain and physical features and as
required by these standards. All monuments shall be solid and
free from movement. They shall be set in the ground at least
to the depth of the length given unless they are encased in
concrete. With the exception of drill holes and cut crosses, the
precise position of the corner shall be marked by a point on a
cap and the cap shall be inscribed with the licensure number
of the professional land surveyor in responsible charge or the
corporate licensure number or name of the company.
(2) Permanent monuments shall be selected from the following:
(A) Concrete monuments consisting of reinforced concrete
at least four inches (4") square or in diameter and no less than
twenty-four inches (24") in length with its precise position
marked by a point on a brass or aluminum cap not less than
one and one-half inch (1 1/2") in diameter;
(B) Commercial cast iron or aluminum survey markers no less
than twenty-four inches (24") in length. Nonferrous markers
shall have ceramic magnets attached to aid in recovery;
(C) Steel, coated steel, or aluminum rod markers not less than
five-eighths inch (5/8") in diameter, iron pipe markers not less
than three-quarter inch (3/4") inside diameter and not less than
twenty-four inches (24") in length. These monuments shall
have a permanently attached cap of the same metal or of a
dissimilar metal if the metals are insulated with a plastic insert
to reduce corrosion. Nonferrous rod markers shall have ceramic
magnets attached to aid in recovery; and
(D) Brass or aluminum disks not less than two inches (2")
in diameter, countersunk and well-cemented in a drill hole
in either solid rock or concrete. Ceramic magnets shall be
attached or installed with the disk to aid in recovery.
(3) Semi-permanent monuments shall be selected from the
following:
(A) Iron pipe markers not less than three-fourths inch (3/4")
outside one half inch (1⁄2") inside diameter, at least eighteen
inches (18") in length, and having a plastic or metal cap;
(B) Steel or aluminum rod markers not less than one-half
inch (1/2") in diameter, and not less than eighteen inches (18")
in length, and having a plastic or aluminum cap;
(C) A cross-cut or drill hole in concrete, brick, stone paving,
or bedrock at the precise position of the corner or on a
prolongation of a boundary line; and
(D) In asphalt paving, cotton picker spindles, railroad spikes
(center punched or chiseled cross), semi-permanent half-inch
(1⁄2") rebar, and magnetic spikes (minimum of 8" in length) that
are solid and not easily removed or destroyed.
AUTHORITY: sections 60.510(7), 60.550, and 448.2-109, RSMo
2016.* Material in this rule was originally covered in 10 CSR 302.060. Original rule filed Dec. 1, 2016, effective June 30, 2017.
*Original authority: 60.510, RSMo 1969, amended 2012, 2013; 60.550, RSMo 1969,
amended 2013; and 448.2-109, RSMo 1983, amended 1988.