19 MAC Pt. 7, R. 8.02

Appliances

Year: 2026Length: 128 wordsOfficial source

Cite as 19 Miss. Admin. Code Pt. 7, R. 8.02

Appliances. 8.02.1 Room Heaters. Unvented room heaters may be installed in residential sleeping quarters and bathrooms provided the aggregate input rating does not exceed 20 BTU’s per hour per cubic foot of room or space in which it is installed. Source: Miss. Code Ann. §§75-57-1, et seq. (Rev. 2009) 8.02.2 Heating Appliances In Stationary Mobile Homes. Vented or Non-vented type circulating room heaters may be installed in stationary mobile homes for use with LP-Gas as follows: A. The appliance must be listed for use with LP-Gas by the American Gas Association or othernationally recognized testing laboratory. B. The appliance must be installed in accordance with NFPA-54 provisions for combustionand circulating air. C. A clayback heater cannot be used; however a heater with a cool-type cabinet may be used.