MAC Pt. 18, R. 3.1.11
On-site Systems Serving Commercial Establishments, Multi-Family
Cite as Miss. Admin. Code Pt. 18, R. 3.1.11
On-site Systems Serving Commercial Establishments, Multi-Family
Residences, Manufactured Home Developments and Recreational Vehicle Campgrounds.
1.
A property owner planning to build, construct or otherwise place more than two families,
manufactured homes or recreational vehicles or a single commercial establishment on a
single tract of land and is planning to utilize an Individual On-site Wastewater Disposal
System, designed to treat and dispose of residential strength wastewater, must submit
information
on
the
Multi-Family
Residence
and
Manufactured
Home
Development/Recreational Vehicle Campground Checklist Form provided by the
Department.
2.
Multi-Family residences must count each separate unit as one “lot” in the development.
3.
The planned sewage flow for each lot in a manufactured home development shall be 390
gallons per day.
4.
More than one commercial establishment, recreational vehicle or multi-family dwelling
may be connected to a single on-site wastewater disposal system, provided that one
person is accountable for the on-site sewage disposal system in accordance with these
regulations for all dwellings involved.
5.
Commercial
establishments,
multi-family
dwellings
and
recreational
vehicle
campgrounds where the connection of more than one dwelling to an on-site sewage
disposal system is proposed, the application to install an on-site disposal system shall
include the information in Rule 3.1.11(2) and the following additional information:
a.
A complete layout of streets, parking areas, on-site sewage disposal systems,
sewer lines, water lines, easements, underground utilities and dwelling locations.
b.
Total acreage or square footage of the proposed property.
c.
A notarized statement signed by the property owner, stating that the property will
not be subdivided or lots sold, and that the on-site sewage disposal system will be
under the responsibility of one person, and giving the name of that person, with
address and telephone number.
d.
For multi-family dwellings, each building plan shall show the number of dwelling
units and number of bedrooms.
6.
Projects with projected wastewater flows in excess of fifteen hundred (1,500) gallons per
day and flows of high strength waste (not typical of domestic sewage waste) must be
designed and submitted by an engineer.
7.
The property involved shall not be developed in excess of its capacity to properly treat
and dispose of sewage flows generated by the project.
8.
The property owner of commercial establishments, recreational vehicle campgrounds or
multi-family dwellings where multiple units are connected to a single onsite system shall
establish covenants running with the land which shall include, at a minimum, the
following:
a.
The responsible person originally owning or developing the property shall own
and be responsible for the operation and maintenance of the common sewage
disposal system(s). The responsible party shall not disestablish itself without the
concurrence of the Department, in which case its responsibilities shall pass to its
successors or assigns.
b.
The covenants shall be binding on present and future owners until such time as
the system(s) is/are no longer required by the Regulation, the same being the case
when each space (lot) is connected to a public or private sanitary sewer system.
9.
Once the developer has assembled the required documentation it must be submitted to the
department for review. Upon completion of the review the developer or his/her agent will
receive authorization to proceed with the project.