11 MAC Pt. 7, R. 2.12
Design Criteria And Construction Standards
Cite as 11 Miss. Admin. Code Pt. 7, R. 2.12
Design Criteria And Construction Standards. The Licensee shall be responsible for
compliance with all applicable state and federal statutes and regulations.
A.
Water Wells and Boreholes Penetrating Aquifers In General Use For Domestic and Public
Water Supply – The standards contained herein are the minimum construction standards
considered necessary for the protection of the state’s high-quality groundwater resources.
Other regulatory programs may be applicable and additional standards may be required for
certain types of facilities, such as Mississippi State Department of Health regulations
governing public supply
wells. If a water well contractor encounters geologic
formations or unusual circumstances that appear to dictate a deviation from the standards,
the contractor shall consult with MDEQ staff regarding proposed construction procedures
for the water well or borehole in question.
(1)
Construction Standards – The following construction standards apply to wells and
boreholes penetrating water bearing strata including but not limited to, potable
water wells, irrigation wells, monitoring wells, observation wells, underground
discharge wells, dewatering wells, saline or brackish water withdrawal wells,
contaminant recovery wells, heat pump water supply holes and vertical closed-
loop system holes, industrial supply wells, cathodic protection wells, rig supply
wells and geotechnical boreholes:
(a)
All water wells and boreholes covered under this section shall be
constructed by a licensed water well contractor unless specifically
exempted by statute.
(b)
Well casing shall terminate not less than twelve (12) inches above
natural ground elevation or, where practicable, above the 100-year
flood elevation. However, if flood levels around the well routinely
exceed a reasonable height for an extended casing above the twelve
(12) inch minimum, then the well shall be fully sealed with a Braden
Casing Head, or approved equivalent, to prevent the flow of flood waters
into the casing. The casing head shall contain a screw-in plug with a
minimum diameter of one-half (1/2) inch to provide access for water level
measurements. If the casing is not covered with a recorder box or pump
housing, then it must have a locked, overlapping cover or other suitable
cover capable of preventing unauthorized access to the casing head and
access plug.
(c)
Public water supply wells shall have the top of the well casing set at least
one (1) foot above the 100-year flood level.
(d)
All wells shall have a check valve installed in the discharge line to
prevent the intentional or accidental introduction of contaminants
into the well. All new unmetered wells larger than six (6) inches in
diameter shall have a minimum of four (4) feet of straight pipe
installed between the casing head and the check valve, and all other
equipment, valves, pressure relief valves, vacuum breakers, and
distribution systems shall be connected on the discharge side of the check
valve.
(e)
All wells, except approved underground discharge wells as specified in
paragraph o. below, shall be constructed in such a manner that the finished
ground elevations around the casing are sloped to drain away from the
casing. Equipment such as engines, pressure tanks, or fuel tanks to be
installed shall be placed on pre-cast concrete blocks or pads to prevent
differential settlement that could result in damage to the pump and the
well.
(f)
The annular space on all wells covered by this section of the regulation
shall be grouted from a depth of at least ten (10) feet below the surface to
the surface, except as specified in paragraphs g, i, j, k, l, m, o, and p
below.
(g)
Wells located within one hundred (100) feet of a potential source
of pollution such as sewers, septic tanks, landfills, and waste and
raw material piles shall be grouted from a depth of at least fifty
(50) feet below the land surface to the surface, except as specified
in paragraphs h, i, j, k, l, n, and o below.
(h)
Potable water wells shall not be constructed within 100 feet of any
potential source of pollution.
(i)
Wells located within one-quarter mile of a known existing area of
contaminated aquifer shall be grouted from the top of the water
bearing stratum to the ground surface, or the top of the casing for
underground discharge wells.
(j)
Outer casing for wells serving public water supply systems shall be
grouted from the top of the target water bearing stratum to the
ground surface.
(k)
monitoring wells shall be grouted from the top of the seal or filter pack to
the ground surface, unless a more stringent requirement is mandated by
other applicable regulatory programs. Specifics of monitoring well
construction shall follow the most stringent requirements of the
applicable regulatory programs.
(l)
Cathodic protection wells shall be grouted from a depth of fifty
(50) feet below ground surface to the ground surface. Wells
constructed with granular material such as gravel from the top of
the anodes to near the surface are prohibited. If wells are no longer
used, the vent pipe, casing or other non-grouted openings shall be
grouted from a depth of at least ten (10) feet below the ground
surface to the ground surface.
(m)
For continuous lengths of grout not separated by multiple screens,
grout shall be introduced in one continuous operation from the top of the
water rearing stratum to the ground surface.
(n)
Grout for all holes covered under this section shall consist of either
neat cement, cement grout, cement-bentonite mixture (5-8%
bentonite), or bentonite. Bentonite pellets or bentonite chips may
be added under free-fall conditions for depths not exceeding
twenty-five (25) feet. Free-fall addition of any other type grout
from the surface is prohibited. Granulated or pelletized bentonite
may be placed to greater depths only if introduced through a tremie
pipe.
(o)
All wells, regardless of size, which are drilled through or into
aquifers containing chloride concentrations in excess of 250
milligrams per liter (mg/l) and/or total dissolved solids (TDS)
concentrations in excess of 1000 milligrams per liter (mg/l), must
be completed using metal casing. Furthermore, all such wells shall
be completed using only the casing method of grouting
(Halliburton method) to grout thoroughly the annular space from
the bottom of the casing to ground surface or to the top of the
casing for underground discharge wells.
(p)
Outer casing for underground discharge domestic wells shall be
grouted from a depth of at least ten (10) feet below the top of the
casing at the underground discharge head, or pitless adapter, to the
top of the casing.
(q)
Public water supply wells shall be constructed in such a manner that any
column/casing vents and blowoff valves are properly screened.
(2)
Disinfection
(a)
All water used in the drilling or construction process and in well
development shall be clean and free of impurities that could
contaminate water bearing sands penetrated by the well or
borehole. For construction and development of a potable water
well, water shall be obtained from a groundwater source of proven
quality such as a domestic well or a public water supply system. If
the water is obtained from a local public water supply distribution
system, it need not have additional chlorine added during the
drilling and/or construction process; otherwise, the water shall be
chlorinated. A residual of free chlorine of not less than 5 parts per
million (ppm) shall be maintained in any water used for well
development.
(b)
Gravel to be placed in potable water wells shall be disinfected with
a solution of at least 50 mg/l free chlorine. (Clean pre-packaged
gravel is exempt from this requirement.)
(c)
Upon completion of drilling potable water wells, the well and
adjacent aquifer shall be disinfected using a solution of at least 50
mg/l free chlorine applied for at least 24 hours. The procedure
shall meet or exceed the American Water Works Association
(AWWA) Standard current at the time of the activity.
(d)
After disinfection, the potable water well shall be pumped until a
chlorine free sample is collected from the well. The sample also
must be free of coliform bacteria. Samples shall be collected,
submitted, and analyzed in accordance with applicable Mississippi
State Department of Health requirements.
B.
Water Wells and Boreholes Constructed in the Mississippi River Valley Alluvial
Aquifer (MRVA) – The MRVA is a uniquely situated shallow aquifer used almost
exclusively for agricultural irrigation with very little potential of increased demand for
domestic or public water supply. Because of the unconsolidated nature of the material and
the predominant agricultural water use, the drilling technique in general use for large
diameter irrigation wells in the MRVA is reverse circulation rotary drilling. Consequently
the standards for construction and disinfection have been modified slightly to reflect the
water usage and drilling practices in the MRVA. If a water well contractor encounters
geologic formations or unusual circumstances that appear to dictate a deviation from the
standards, the contractor shall consult with MDEQ staff regarding proposed construction
procedures for the water well or borehole in question.
(1)
Construction Standards – The following construction standards apply to
irrigation wells screened and completed in the MRVA and to boreholes
that do not penetrate the base of the MRVA, including but not limited to,
irrigation wells, monitoring wells, observation wells, and geotechnical
boreholes:
(a)
All water wells and boreholes covered under this section shall be
constructed by a licensed water well contractor unless specifically
exempted by statute.
(b)
Well casing shall terminate not less than twelve (12) inches above
natural ground elevation or, where practicable, above the 100-year
flood elevation. However, if flood levels around the well
routinely exceed a reasonable height for an extended casing above
the twelve (12) inch minimum, then the well shall be fully sealed
with a Braden Casing Head, or approved equivalent, to prevent the
flow of flood waters into the casing. The casing head shall contain
a screw-in plug with a minimum diameter of one-half (1/2) inch to
provide access for water level measurements. If the casing is not
covered with a recorder box or pump housing, then it must have a
locked, overlapping cover or other suitable cover capable of
preventing unauthorized access to the casing head and access plug.
(c)
All wells shall have a check valve installed in the discharge line to
prevent the intentional or accidental introduction of contaminants into
the well. All new unmetered wells larger than six (6) inches in
diameter shall have a minimum of four (4) feet of straight pipe
installed between the casing head and the check valve, and all other
equipment, valves, pressure relief valves, vacuum breakers, and
distribution systems shall be connected on the discharge side of the check
valve.
(d)
All wells, except approved underground discharge wells, shall be
constructed in such a manner that the finished ground elevations
around the casing are sloped to drain away from the casing.
Equipment such as engines, pressure tanks, or fuel tanks to be
installed shall be placed on pre-cast concrete blocks or pads to
prevent differential settlement that could result in damage to the
pump and the well.
(e)
The annular space on all wells covered by this section of the
regulation shall be grouted or sealed with bentonite from the
lowest level of disturbed earth immediately adjacent to the casing
down to a depth of at least ten (10) feet below that level, except as
specified in paragraphs of. and g. below.
(f)
Wells located within one hundred (100) feet of a potential source of
pollution such as sewers, septic tanks, landfills, and waste and raw
material piles shall be grouted from the lowest level of disturbed earth
immediately adjacent to the casing down to a depth of at least fifty (50)
feet below that level, except as specified in paragraph g. below.
(g)
Wells located within one-quarter mile of a known existing area of
contaminated aquifer shall be grouted from the lowest level of
disturbed earth immediately adjacent to the casing to the top of the
water bearing stratum.
(h)
Grout for all holes covered under this section shall consist of either
neat cement, cement grout, cement-bentonite mixture (5-8%
bentonite), or bentonite. Bentonite pellets or bentonite chips may
be added under free-fall conditions for depths not exceeding
twenty-five (25) feet. Freefall addition of any other type grout
from the surface is prohibited. Granulated or pelletized bentonite
may be placed to greater depths only if introduced through a tremie
pipe.
(2)
Drilling Fluids and Disinfection
(a)
All water used in the drilling or construction process and in well
development for non-potable water wells in the MRVA shall be dosed
to a minimum concentration of fifty parts per million (50 ppm) of
chlorine, i.e., two (2) gallons of sodium hypochlorite (laundry bleach,
approximately five percent (5%) available chlorine) per one thousand
(1000) gallons of drilling water.
(b)
The licensee shall denote on the driller’s log portion of the State Well
Report the location of the source of any surface water used as well as
the method of dosing and the volume of chlorine used in the drilling
and development of a non-potable water well in the MRVA.
(c)
Equipment used in the transport, storage, or circulation of surface water
during the drilling and development of a non-potable water well in the
MRVA shall not be used thereafter in the drilling and development of a
potable water well without having first been disinfected with a solution
of at least fifty parts per million (50 ppm) free chlorine for a minimum
contact time of twenty-four (24) hours.