15 MAC Pt. 21, R. 1.9.11
Radiation Monitoring Requirements
Cite as 15 Miss. Admin. Code Pt. 21, R. 1.9.11
Radiation Monitoring Requirements.
1.
There shall be available, at each particle accelerator facility, appropriate portable
monitoring equipment which is operable and has been appropriately calibrated for
the radiations being produced at the facility. Such equipment shall be tested for
proper operation daily and calibrated at intervals not to exceed one year and after
each servicing and repair.
2.
A radiation protection survey shall be performed and documented by a qualified
expert, acceptable to the Agency, when changes have been made in shielding,
operation, equipment, or occupancy of adjacent areas.
3.
Radiation levels in all high radiation areas shall be continuously
monitored. The monitoring devices shall be electrically independent of the
accelerator control and safety interlock systems and capable of providing a read-
out at the control panel.
4.
All area monitors shall be calibrated at intervals not to exceed one year and
after each servicing and repair.
5.
Whenever applicable, periodic surveys shall be made to determine the amount of
airborne particulate radioactivity present.
6.
Whenever applicable, periodic smear surveys shall be made to determine the
degree of contamination.
7.
All surveys shall be made in accordance with the written procedures established
by a qualified expert, acceptable to the Agency, or the radiation safety
officer.
8.
Records of all radiation protection surveys, calibrations, and instrumentation tests
shall be maintained at the accelerator facility for inspection by the Agency.